A split system shows in three places: the indoor head on the wall, the pipe run between the units, and the outdoor unit on a slab, bracket or stand. SE Heating and Cooling, a Melbourne installer, notes that outdoor units "can be on concrete slabs, wall brackets, or ground stands, depending on how the property is laid out". A multi-head system adds more heads to one outdoor unit, and Climate Control Solutions puts it at "2 to 5 indoor heads without any ductwork". Where the outdoor unit goes matters more in Bayside than in many councils: on a property in a Heritage Overlay, Bayside's planning scheme Clause 15.03-1L says to "Site all ancillary services, including satellite dishes, air conditioning plants, solar heating systems, garbage facilities and the like, so they are concealed from the street", so a well placed condenser on such a house sits to the side or rear, out of sight from the footpath. The design and installation side of this work is covered on the split system installation page and the wider air conditioning installation page.
A well hung split system head starts with the wall plate. Mitsubishi Electric's MSZ-AP installation manual says to "Find a structural material such as a stud in the wall and fix installation plate horizontally", then to hook the indoor unit on and check it "by moving the unit to left and right". In a photo, that shows as a head whose top edge runs parallel to the cornice and the ceiling line, with a small even gap below the cornice rather than a body jammed hard against it or tilted to one side. The same manual lists the indoor spot as "Where air flow is not blocked", "Where cool or warm air spreads over the entire room" and "Where the air filter can be removed and replaced easily". Curtains are the common blocker: a head set where drapes or a pelmet hang across its louvres pushes air into fabric instead of the room, and Daikin's troubleshooting page lists areas next to the unit "blocked by furniture" among the first checks when a room does not cool or heat well. Faint marks on the ceiling above an older head are not a fault in the fixing either, since Mitsubishi Electric's MSZ-AP operating instructions put smudges around the unit down to "dust in the air due to air circulation".
A multi-head system puts more pipework on the outside wall than a single split, because each indoor head has its own refrigerant lines and wiring back to the one outdoor unit. Mitsubishi Electric's multi-head page says the "Proper connection of refrigerant lines and electrical wiring between the indoor and outdoor unit connected setups is essential". The tidy result is a single route: the runs from each head brought together and carried down the wall side by side inside one cover to the outdoor unit, rather than two or three separate pipes crossing the brickwork at different angles. The MSZ-AP installation manual gives the reasons the cover matters: "embed or protect the refrigerant piping", "For outdoor unit side, surely insulate every piping including valves", and keep each bend to a radius of "100 mm or more" so the pipe is not crushed. Painting the cover to match the wall makes the run read as part of the house; whether it is painted, and in what colour, is a finishing detail to settle on the quote. On a Heritage Overlay property, Bayside's Clause 15.03-1L also says "Discourage the painting of unpainted surfaces", which reads as a reason to keep the paint on the cover and never on the face brick around it.
A ducted system keeps its working parts out of sight. The indoor unit sits in the roof space or under the floor, flexible ducts run to each room, and the outdoor unit stands outside. Inside the house, only three things show: the outlets in the ceilings, the return air grille, and the controller on the wall. Those three carry the finish, so they are what a gallery of ducted work should show. The Australian Government's YourHome guide says "Ducts should be the correct size and have adjustable outlets", and it warns that without a proper return air path "the conditioned air escapes and the system sucks unconditioned air in". A neat return air grille in a hallway ceiling or wall is the visible sign that the return path was planned. Sizing, zoning layouts and roof-space work are explained on the ducted air conditioning page.
Ceiling outlets are the face of a ducted system, and both round and square ones are on the market. Lawson Air, an Australian ducted installer, says "The most common type of grille for a ducted installation is the Round Ceiling Grille (or Diffuser)", and Brivis's ducted gas heater installer's manual uses "150mm round ceiling diffusers, with 150mm ductwork connection" as its typical example. For a square face, Expella, an Australian grille maker, lists a square "flangeless internal ceiling grille that sits flush with the ceiling", sold in an "Insulated (for air conditioning)" version. Whatever the shape, neat work looks the same: a hole cut to the outlet's size so the rim covers the edge with no gap, plaster around it with no cracks or crumbled edges, no chipped cornice where the outlet sits near a wall, and outlets spaced so they line up with the room rather than landing wherever a duct happened to end. YourHome adds that outlets should be adjustable, and the Brivis manual says registers and diffusers "should be large enough and of good design. They should minimise noise", so a quiet outlet is part of a good finish, and a noisy one is worth raising with the installer.
The controller is often the only part of a zoned ducted system that sits at eye level, so it shows the care taken more than any other part. On Mitsubishi Electric's zone controller, the zone controller interface and the wireless receiver are both listed as "concealed in ceiling", which leaves only the controller itself on the wall. When an older system is upgraded, the same brochure describes a backing plate "to cover the old controller area", so a replacement controller should not leave a patch of unpainted plaster or old screw holes around it. Placement matters because many controllers also read the room temperature: Mitsubishi Electric's ducted page lists temperature sensors in the indoor unit, the wall controller or the zone controller, and Brivis's installer's manual puts its heater thermostat on an internal wall in the living area, "approximately 1500mm above the floor level", away from warm air outlets, sun, draughts and return air inlets. Other makers follow the same pattern: Daikin's ducted wired controller has zone buttons to choose the rooms, and says "The Airflow per zone is set by your installer during the commissioning stage", and Braemar's gas heater manual covers its MagIQtouch controller. A level screen, no visible cable, and a spot away from heat and draughts are the signs of a good install.
Two different kinds of heating show up inside a home in two different places. Reverse cycle heating comes from a heat pump: Mitsubishi Electric explains heat pump heating as "heat energy is drawn from the outside air", and a floor console delivers that heat low in the room. Gas ducted heating burns gas in a heater cabinet outside or in the roof space, then pushes warm air through ducts to registers in each room, and in a house with timber floors those registers sit in the boards. A gallery of heating work should therefore show the indoor console or the floor register, plus the outdoor unit or heater cabinet that feeds it. The heat pump side is covered on the reverse cycle air conditioning page, and new gas heaters and their duct runs on the ducted heating page.
A floor console is the reverse cycle option for walls with no room higher up, and the makers sell it for exactly those spots. Daikin says its floor standing units suit "Rooms or areas where upper wall installation isn't possible" and "can even be semi-recessed into the wall or in an unused fireplace". Mitsubishi Electric describes its floor consoles as "a great renovation option, fitting neatly into cavities of renovated fireplaces or heaters", with the MFZ-KW series listing an "Unobtrusive recess installation". Under a window, where the wall above is glass, a console fills the space below the sill; in a photo, look for a unit set square to the sill and skirting, with curtains that stop above its grille rather than hanging over it. Beside or inside an old fireplace, look for a unit centred in the opening with the surround left intact and the gap around the console trimmed neatly. These units heat from low down: Mitsubishi Electric says "Heating is introduced at floor level", and Daikin's "Floor warming" works from the bottom louvre. On a heritage property, Bayside City Council's heritage page says "A permit is not required for internal alterations unless it is one of the few properties that have specific internal controls", so a fireplace recess on a listed house is worth checking against the schedule first.
In a house with suspended timber floors, gas ducted heating usually comes up through registers cut into the boards. Brivis's installer's manual gives "300mm x 100mm floor registers" as its typical floor outlet, so a register of that kind is a small rectangle lying in the floor, often near an outside wall. None of the manuals read for this page sets a rule for how a register sits in the boards, so "flush" here is the finish to ask for rather than a manual requirement: an opening cut cleanly to the register's size, no split or lifted boards around it, and a frame that sits flat with no lip to catch a foot or a chair leg. What sits on top of the register matters too. Braemar's manual says "DO NOT FIT FILTERS TO WARM AIR OUTLET REGISTERS", and where outlets are closed and the fan speed turned down "at least 1 outlet must remain open at all times", while the Brivis manual says a minimum number of outlets must stay open for the heater "to operate properly without overheating". A register buried under a rug or a couch works much like a closed one. Better Health's gas heating page adds that registers should be vacuumed out with the heater off and cool.
An evaporative cooler is a cabinet on the roof that draws outside air through water-soaked pads and blows it down a dropper duct into ceiling outlets. The parts that photograph are the cabinet itself, the flashing where it meets the roof, the drain pipe running down the roof, and the pads inside the side panels. Much of the evaporative work in established homes is servicing, repair and like-for-like replacement: The Quote Yard, a Victorian cost guide, describes the usual replacement as "the new unit mounted on the existing roof curb and connected to the existing ductwork, water supply, and electrical circuit". On a property in a Heritage Overlay, the same Bayside Clause 15.03-1L that covers condensers names "air conditioning plants" among the services to be concealed from the street, which is worth checking with Bayside City Council before a cabinet moves to a more visible spot. Servicing, pad work and fault finding are on the evaporative cooler service and repairs page.
Seeley International's installation manual for its BMQ, CPQ, LCQ, TBQ and TBS coolers (the Braemar, Coolair and Breezair lines) sets out what a seated cabinet should look like, and its rules are the same on a tiled roof or a metal one. The dropper duct is fixed "to the roof structure on 3 sides" and must be "level and square in all directions (use a spirit level)", and the transition is checked "with a spirit level placed across the flats in both directions". It also says the dropper "must never sit directly on ceiling joists or beams, as this may cause noise or vibration issues", and "If the roof is structurally inadequate, provide an alternate load bearing structure". In a photo, a level cabinet sits upright against the pitch of the roof, with the flashing dressed around the dropper to suit tiles or sheeting so water runs past it. Spacing is visible too: the manual asks for 1.5m from a gas flue, 3m from a solid fuel heater flue, 1.0m from solar panels, 5m from a sewer vent and 600mm from a wall. The drain matters as much: "Never drain water from the cooler directly on to the roof", and the drain pipe needs "a constant slope (without undulations) towards the ground", secured to the roof.
Pads are the one part of an evaporative cooler where a before and after photo tells the whole story. New pads sit evenly in their frames with no gaps at the edges, and Seeley's installation manual explains why fit matters: "Incorrect fitment may allow water to bypass the pad and be carried over into the air stream and ducting". Scaled pads carry a crust of mineral deposit, and Seeley's troubleshooting table lists "Heavy pad deposits. Clean or replace pads". The Quote Yard says "Melbourne's water supply is generally soft with low mineral content", while harder water "accelerate[s] scale formation on the filter pads". Clogged pads are packed with dust and debris, listed by Seeley as "Clogged or dirty cooling pads", and The Quote Yard warns that "a system with clogged pads pushes warm air while running exactly as it always did". Dry streaks are a third sign: Seeley's Coolair and Braemar manual asks the technician to "Check the pads are wetting evenly" and warns "Do not damage the pads with high pressure water spray". New pads come with one more step, since the installation manual calls for flushing water through them and draining the tank "To prevent initial start-up odours".
Maintenance work is the hardest to show in a single photo, so before and after pairs do the job. Routine servicing leaves its own visible signs even where nothing was broken: filters washed and back in place, a condensate drain that runs clear, an outdoor unit cleared of leaves (Daikin's split range page says to "Keep the outdoor unit free from debris like leaves or dust"), and on a gas ducted system, the heater cabinet opened up for its check. The other sign is the paperwork. The Quote Yard's servicing guide says "What a service record should contain is more than a receipt for payment" and advises "Ask to see the checklist before you book anything", and Braemar's ducted gas heater manual carries a maintenance schedule with columns for the "Name of Technician and company", a signature and the "Date of attendance". Near the bay, The Quote Yard adds that outdoor units "in the bayside suburbs from Williamstown around through Brighton" corrode at the coil and cabinet, which a before photo of the outdoor coil often shows. Service visits are explained on the air conditioning service page, and gas heater servicing on the ducted heating service and repairs page.
This part is about the unit, not health. Mr Duct Cleaning, a Melbourne cleaner, explains where the build-up sits: water from cooling stays "on the coil, the barrel fan and in the drain tray", and the coil and barrel fan are "the parts that grow mould and cause the smell". A before photo usually shows dusty filters and what Mr Duct lists as "Black specks or dark marks on the louvres", and Mr Duct itself lists "before and after photos" as part of its clean. An after photo shows clean filters, coil fins that are bright and straight, and a fan with clear blades. The process behind the after shot is part of the evidence: Mr Duct lists the room covered with a wash bag under the unit, "Coil and fins foamed and brushed", "Barrel fan scrubbed", a "Low pressure rinse ... into the bag, not onto your wall", and the outdoor unit cleared of "Leaves, dust and cobwebs". It also warns that budget deals covering "a filter wash, a wipe of the cover and an antibacterial spray" leave the coil and barrel fan dirty, and that spraying without covers can "bend the fins". Bent fins or a stained wall under the head in an after photo are the signs to question. The full clean is set out on the aircon cleaning page.
Two repairs show up well in photos. A cleared drain line means water running freely from the hose end outside again; Mitsubishi Electric's MSZ-AP operating instructions say to "check whether water is being discharged from the drain hose outside" when a head leaks, and that "Obstructions and bends in the drain hose" cause the trouble. A replaced outdoor fan blade looks whole and true behind the grille, where the old one was chipped or cracked; The Quote Yard says "Debris entering the outdoor unit, hail, or a blade cracking with age all cause imbalance and noise". Fault finding behind both jobs is on the air conditioning repair page.
Commercial work in shops, offices and cafes shows differently from a home, because the indoor units often sit in a suspended ceiling and the outdoor plant is grouped together on a roof or a rear wall. Mitsubishi Electric's light commercial range "includes wall-mounted, ceiling cassette, ducted, and under-ceiling models", and the same page says wall mounted and ceiling suspended units suit "heritage sites, hospitality venues or tenanted properties where building modifications are limited". A gallery of commercial work should show the indoor units against the ceiling they sit in, and the outdoor units with the space and fixings around them. Ceiling cassettes, plant layout and maintenance for business premises are covered on the commercial air conditioning page.
A ceiling cassette is built to sit in a suspended ceiling, so the ceiling grid is the guide to whether it was fitted well. Mitsubishi Electric says its SLZ-M cassette is "Designed to fit into 600 mm x 600 mm suspended ceiling grids", and that its larger PLA-M cassette "mounts flush within suspended ceilings". In a photo, a well fitted cassette takes the place of a ceiling tile, square to the grid bars and in the same row as the light panels and other fittings, with its panel sitting level and no gap or sag along the edges. A cassette set off the grid, straddling a bar or butted against a light fitting, is the opposite. Cassettes also hide their drain: both Mitsubishi Electric cassette pages list a built-in drain pump, so there should be no drain hose running across the ceiling. Access is part of the finish as well, since the SLZ-M page states "Suitable access for warranty and service is required", which in a tiled ceiling means the tiles around the cassette lift out cleanly for a technician.
Business premises with several indoor units often group the outdoor units in one place, on a roof frame or on brackets along a rear wall. Mitsubishi Electric's PUZ-ZM outdoor unit installation manual sets out what a sound group looks like: "Leave 50 mm space or more between the units", no more than three side by side where there are obstacles behind and above, and "The units can be stacked up to two units high". Each unit sits on "a sturdy, level surface to prevent rattling noises", fixed with "four-M10 foundation bolts". On an open roof, the manual says to turn the air outlet away from strong winds, for example facing "the nearest available wall about 500 mm away". It also asks that "Refrigerant pipes connection shall be accessible for maintenance purposes". For wall brackets, Mitsubishi Electric's MSZ-AP manual says "When installing the unit at a high level, be sure to secure the unit legs". Noise matters on a rear wall facing homes: EPA Victoria says "Lower levels generally apply in residential or rural living areas". The handover logbook named in the ARC code belongs with the plant.