Ducted heating Brighton VIC 3186 moves warm air from one central heater through insulated ducts to an outlet in each room on the duct plan. Peak Air Conditioning Brighton quotes new and replacement gas ducted heaters, electric ducted systems for homes moving off gas, and the ducts, outlets and return air that carry the heat. The heater's position in the roof, under the floor or on an outdoor pad, the size of the gas pipe and meter, and the flue route are all checked at an inspection before the written quote is prepared. Gas work is done by a licensed gasfitter registered with the Building and Plumbing Commission, and the 220 to 240 volt wiring by a licensed electrician. Enquiries are taken from 6am to 10pm, seven days a week.
GET A FREE QUOTE
Two things shape how a heating or cooling job in Brighton starts: knowing what each option costs before anything is booked, and finding a visit time that suits the household. Peak Air Conditioning Brighton is set up around both. Prices are put in writing after the site visit, option by option, and the phone line takes bookings for new systems, servicing, aircon cleaning and repairs from 6am to 10pm, seven days a week.
Peak Air Conditioning Brighton
A ducted heating system is one heater and a network of ducts, and the first decision is what powers the heater. YourHome, the Australian Government's guide to sustainable homes, describes ducted air heaters as systems that circulate hot air through roof or underfloor ducts, supplying convective heat, and notes that they can make that heat from gas or from electricity. The three parts below set out the gas range by star rating, the electric route for a home without gas, and which of these systems can also cool.
Rinnai, which now sells the Brivis range, lists its gas ducted heaters on its Brivis page, read on 20 November 2026, across the full span of gas star ratings. The StarPro 6 carries a 6 star gas energy efficiency rating in 15.0, 23.0, 29.0 and 35.0 kW sizes, and the StarPro 5 and StarPro 4 carry 5 and 4 stars in 21, 30 and 35 kW. The Buffalo BX5C is listed as high efficiency 5 star at 20 and 30 kW, the Buffalo BX3C as 3 star at 15.5, 20 and 26 kW, the Classic Compact as 3.0 star and the Classic Wombat at 3.8.
Braemar, a Seeley International brand, describes one of its heaters as the world's first 7 star equivalent ducted gas heater. Its footnote explains that this is a star rating equivalent based on the Australian Gas Association's results under the AS/NZS 5263.1.6:2020 test method, so it is a calculated equivalent rather than a seventh star on the same label.
The rating also changes the install. Braemar's owner's manual refers to non-condensing 5 star heaters, which implies that some heaters at 5 stars and above are condensing models, and Brivis's operation manual lists a condensate drain on its StarPro 6. A condensing heater therefore needs a drain point planned into the job, alongside the flue and gas supply. The star rating and kW size that suit a home are set by its heat load rather than by what the range offers, and both are confirmed at the inspection before they go on the written quote.
Electric ducted heating suits a home that has no gas, or one moving away from it. The Victorian Government's new buildings page, read on 20 November 2026, says existing buildings without a gas connection cannot be connected to gas from 1 January 2027, so for those homes electric is the only ducted choice from that date.
Electric ducted heating covers two quite different machines. The older one is the central electric resistance ducted heater, which the Victorian Energy Upgrades page defines as a stand-alone heating unit designed for installation with ducts, serving a floor area of at least 100 square metres. It is one of the systems the program lists for replacement by ducted reverse cycle, so a home that already runs one is starting from the system the program pays to remove.
The current one is a ducted heat pump, sold as ducted reverse cycle air conditioning. Rinnai's ducted range is reverse cycle in every model, from 7.0 to 24.0 kW, and it is sold under the Rinnai name: brivis.com.au now says Brivis is part of Rinnai, and neither site lists a Brivis-branded electric ducted system on the date read. Consumer Affairs Victoria's rental heating standard gives a useful benchmark for efficiency: an electric ducted heating system with a GEMS Heating Seasonal Performance Factor of 3.2 or above. A heat pump system adds an outdoor unit that needs its own position, and the home's electrical supply has to carry it, which the cost section returns to.
A gas ducted heater heats only. Whatsthedamage's Melbourne cost guide puts it in one line: gas ducted only heats, and it needs a gas connection and a flue. Cooling through the same outlets comes one of two ways.
The first keeps the gas heater and adds a cooling coil and an outdoor unit to the duct network. Rinnai lists Brivis ICE and DualComfort add-on cooling as compatible with its StarPro series and ICEbox DualComfort with its Buffalo series, and Seeley International lists ducted add-on cooling systems in its Braemar range. The second route replaces the gas heater with an electric reverse cycle ducted system that heats and cools from one machine.
Compatibility is decided model by model, and the Brivis Classic installer's manual shows why. It says Classic ducted gas heaters do not have on-board add-on cooling connections, that an ICE unit fitted to a Classic needs an extra relay, and that Classic heaters should not be installed downstream of an air washer or a refrigerative cooling system. YourHome adds that ducts need to be larger if they are also used for cooling, so ducts sized for heating alone may not suit either route without changes. The cooling installs themselves, add-on coils included, are set out under ducted air conditioning; this page stays on the heating side.
Peak Air Conditioning Brighton
A gas ducted install is four jobs that meet at the heater: where it sits, how gas reaches it, where its flue discharges, and how the ducts carry its air. The figures below come from the Brivis Classic installer's manual, which covers the BX3 external and 2PWN internal heaters and states its clearances in accordance with AS 5601. Other makers publish their own manuals, and the manual for the chosen model is the one that applies. The Brivis manual is clear about its own limits: it covers the heater, its commissioning and its flue configurations, and does not cover the actual ducting design required to suit the installation.
The Brivis Classic range shows the three places a gas ducted heater can sit, and each comes with its own rules. The BX3 is designed to be installed outside the house only. On the ground it stands on a level concrete base or pad with surface water drained away from it; in an elevated position or on a roof it must comply with AS 5601, be secured to prevent movement and have adequate service access. Its service clearances are 500 mm at the front, 300 mm at each end and 1,000 mm clear above the whole roof of the heater, and where its ducts enter the wall, flashing keeps them weather protected. Braemar's owner's manual adds one plain rule for an outdoor heater: do not enclose it.
The 2PWN goes in the roof or under the floor. In a roof space the manual asks for fixed access, a normal ladder or steps, a 600 mm passage from the roof access opening with a walkway of at least 19 mm particle board, a permanent level platform reaching 750 mm out from the controls and fan access sides along the whole heater, and permanent lighting switched at the access opening. Under the floor it asks for at least 200 mm between any part of the heater and the lowest part of the floor structure, a 50 mm concrete base with seepage drained, and a position within 2 m of the access opening or 1.2 m of clearance along the route. Homeupkeep's Melbourne guide observes that external cabinet units are the cheapest to service, a cost-guide view that is weighed at the quote against where an outdoor heater's flue can discharge.
The Brivis manual puts the gas rule in one sentence: the gas pipe and gas meter should be sized so the heater keeps its required incoming gas pressure at maximum consumption, with every other gas appliance in the house running at its maximum at the same time. That is why the heater's size reaches back to the meter. Rinnai's Brivis page bases heater size on total floor area, ceiling height, insulation and glazing, orientation and climate zone, and says installers use a whole-of-home heat load calculation; the kW that comes out of it sets how much gas the pipe must carry.
At commissioning the manual has the supply pressure read on a manometer while the other gas appliances run at full capacity. If it falls below 1.1 kPa, the incoming supply is inadequate and the pipe and meter sizing are checked. Brivis's StarPro service manual explains what low inlet pressure leads to: unreliable ignition and underrated heat output, so a heater that never quite warms the house can be a gas supply problem rather than a heater one. The manual also asks for a gas cock beside the heater in a convenient spot, a G3/4 compression connection, all piping to AS 5601 and a leak test with a soapy water solution or a leak detector spray. It states that the gas supply must be installed by a licensed gasfitter. Where an extension adds rooms to the duct plan, the Victorian Government's existing-homes page, read on 20 November 2026, says gas supply can be increased or extended to service new parts of an existing building.
An external heater's flue discharges right beside the house, so the Brivis manual sets minimum distances measured from the edges of the flue, which it states are in accordance with AS 5601. They include 300 mm horizontally from an openable window or door, 500 mm from an electricity meter or fuse box with the prohibited area running down to ground level, 1,000 mm vertically below an openable window, 1,000 mm from a gas meter, and 1,500 mm in the direction of discharge from an openable window, door or other opening into the building. Shorter distances apply to a drain or soil pipe (75 mm), the wall behind the unit (150 mm), and other flue terminals, return walls, the ground and eaves (300 mm).
Covered or recessed spots have a rule of their own: the covered area must be fully open on at least two sides, or, where only one side is open, the terminal must sit within 500 mm of that opening and discharge towards it. Internal heaters in the roof or under the floor run a flue to the outside instead. The manual asks for a rise of at least 20 mm per metre on horizontal runs, wall terminations at least 300 mm above ground, a maximum length of 6 m for twin wall flue and 2 m for single wall, and no more than two 90 degree elbows; Brivis's Remote Flue terminal is typically used for underfloor installs. Braemar's owner's manual recommends a flue guard on its 3, 4 and non-condensing 5 star heaters where children may be able to touch the flue terminal. On a narrow side path, these distances can decide the heater's position before anything else does.
The ducts carry the heat, and the Brivis manual sets their standard. Ductwork should be well insulated and airtight, with a minimum insulation rating of R1.0, or R1.5 in some areas, and should comply with the Building Code of Australia. The manual adds that it is mandatory under building codes to install insulated fire rated duct on its heaters.
The rating is only part of the job. The manual asks for ducts that are correctly sized, with curves and bends smooth enough for the air to flow efficiently and quietly with minimal resistance, and fastened to the heater's pops, outlet boots and neck adapters with duct tape in accordance with AS 4254, the ductwork standard it names. YourHome gives the reasons from the energy side: ducted systems risk condensation, air leakage and heat loss through the ducts if they are not adequately insulated and sealed, and ducts should preferably sit within the heated space for efficient performance. Energy.gov.au adds that ducted gas heating uses electricity for its fans as well as gas, so heat lost along a duct is paid for twice.
Where an old heater is replaced, the existing ducts are checked against this standard before anyone assumes they can stay. Crushed runs, thin or missing insulation and ducts sized for a smaller heater are the cases the cost guides price as a separate duct job, covered in the cost section below. Whatsthedamage's Melbourne table prices that job as new insulated flexible ducts through the whole house.
Peak Air Conditioning Brighton
The two parts below cover the paperwork and the rule book behind a gas ducted install, which is what an owner can still check once the installer has left. Peak Air Conditioning Brighton quotes in writing after an inspection, and the written quote names the heater model and its star rating, the kW size, the heater position, the flue route, the duct and outlet count, and which licensed trade carries out the gas work and the electrical work. The phone line is answered from 6 in the morning until 10 at night, seven days a week, so a quote visit can be booked around work hours.
A gas ducted heater is a Type A gas appliance: Energy Safe Victoria's classification lists central heaters among the domestic appliances in that group. The Building and Plumbing Commission's compliance certificate page, last updated 9 July 2026, says a certificate must be issued for the installation, relocation or replacement of any Type A gas-using appliance, regardless of the cost, and for the installation, modification or relocation of consumer gas piping. It must be issued to the customer within five days of completing the plumbing work and lodged with the Commission in the same window, and only licensed plumbers can issue one.
For a ducted heater that covers both halves of the job: the heater itself, and any new or altered gas pipe from the meter. The certificate is the owner's record that the gas work was done by a licensed gasfitter registered with the Building and Plumbing Commission, and it belongs in the same folder as the heater's manual, since it shows who did the work and when. Better Health suggests two ways to check a gasfitter's licence before the work starts: on the Commission's website, or by asking to see the tradesperson's licence card, which states what kinds of work the holder is allowed to do.
The electrical side has its own record. The Brivis Classic manual says a licensed electrician must install the 220 to 240 volt wiring, and the heater plugs into a fixed switched 10 amp socket beside it. Its final installation step is to issue any required documentation, and it gives a Certificate of Compliance and a Certificate of Electrical Safety as its examples, so a complete install leaves the owner with paper for both trades.
Brivis's operation manual for its ducted gas heaters opens with two rules. The appliance must be installed, serviced and removed only by an authorised person, who holds the licensing and insurance required by the state gas regulator and issues any required compliance certificates for the work. It must also be installed to the manufacturer's instructions and to AS/NZS 5601, AS/NZS 5141 and AS 4254. Braemar's owner's manual says the same in its own words: its heaters must be installed and serviced by authorised personnel only, and must not be modified.
AS/NZS 5601 is the gas installations standard. It is sold by Standards Australia, so this page quotes no clause from it; the distances given above are the Brivis manual's own figures, which the manual states are in accordance with AS 5601. The manufacturer's manual matters because it is specific to the model in ways a general standard is not. The Brivis Classic manual sets a minimum return air grille size for each model, a minimum and maximum number of open outlets for each model, the fan setting for each outlet type, and the final checks before the heater is handed over, and it bases its guidance on Australian Standards while pointing to local codes for anything outside them.
The manufacturer warranty applies when installed to the manufacturer's requirements. A fair question for any quote, from any installer, is which model and which installation manual it was written against, because the clearances, outlet counts and commissioning settings on site should match the heater named on the page.
Peak Air Conditioning Brighton
The figures below are indicative ranges from Melbourne cost guides, each attributed to its guide; none is this business's price, and the written quote follows an inspection of the heater position, gas supply, flue route and ducts. Brighton's housing spreads the jobs widely. The ABS 2021 Census counts 57.2% of Brighton's occupied dwellings as separate houses, against 73.4% for Victoria, with 22.4% semi-detached, row or terrace houses and townhouses and 19.8% flats or apartments, and 33.1% of homes have 4 or more bedrooms.
Homeupkeep's Melbourne gas ducted page, last updated 14 June 2026, prices supply and install by star rating and size: a 3-star 16 kW heater at $3,800 to $5,200, a 4-star 20 kW at $4,800 to $6,400, a 5-star 23 kW at $5,800 to $7,800 and a 6-star 30 kW at $7,200 to $10,000. Its table pairs each size with a home type, from a 2-bedroom unit or townhouse up to a 4-bedroom or two-storey house, but that pairing is the guide's shorthand: Rinnai's Brivis page sends sizing to a whole-of-home heat load calculation, and that result settles the kW. The guide's brand labels also disagree with the manufacturer. It calls a 20 kW Brivis Buffalo 4-star, while Rinnai lists the Buffalo BX5C as 5 star and the BX3C as 3 star, so no model is named here against the guide's prices.
Whatsthedamage's Melbourne table, updated November 2026, gives a wider band for gas ducted heating supplied and installed: $4,000 to $11,550, with $7,350 typical. The same guide lists what moves a ducted heating quote: the number of outlets and zones, roof space and access, the unit size, any new gas line or meter upgrade, and removal of the old system, which it says is usually quoted separately. Its advice is to ask for the unit model, its kilowatt rating and the duct-and-outlet count on every quote, which is what makes two quotes comparable.
A conversion swaps the gas heater for a ducted reverse cycle system, so it is priced as a ducted air conditioning install rather than a heater swap. Whatsthedamage's Melbourne table puts a standard ducted reverse cycle system, for a 3-bedroom home or a single-storey 4-bedroom with good roof access, at $8,400 to $14,700 ($11,550 typical). A premium or zoned system, for a larger 4-bedroom and up, a two-storey home or room-by-room zoning, runs $12,600 to $23,100 ($16,800 typical).
Against that, the Victorian Energy Upgrades page, last updated 29 October 2026 and read in full on 20 November 2026, lists indicative household discounts for replacing a ducted gas heater with ducted reverse cycle of up to $2,520 at 10 kW, up to $4,200 at 16 kW and up to $5,530 at 22.4 kW. The page says the upgrade must be done by an accredited provider or an installer working with one, that retrospective discounts are typically not possible, and that a replaced system must be in a property more than 2 years old. How those discounts apply to a particular system is set out under air conditioning installation.
Two more lines can appear on a conversion quote. Whatsthedamage notes that a switchboard that cannot carry a reverse cycle unit is a separate line, and the Victorian Government's all-electric page raises the same question of 3-phase power or a switchboard upgrade for a home that electrifies. The old gas heater also has to be disconnected and its supply capped by a licensed gasfitter. Whether the existing ducts can be reused is the other large variable, and it is priced next.
Whatsthedamage's Melbourne table prices whole-house heating ductwork replacement at $2,000 to $6,300, with $3,775 typical, supplied and installed as new insulated flexible ducts. That row covers the ducts only, not the heater, and the guide describes it as the job to price when the heater is sound but the ducts are crushed, leaking or sized for a smaller unit.
It works in the other direction as well. The same guide says that if the ductwork is sound, replacing just the heater unit usually costs less than a new system, and that reusing sound ductwork is the single biggest saving available on a ducted quote. Rinnai's ducted air conditioner page adds that ducting may last longer than the mechanical components. Which way a job goes is settled at the inspection: the duct insulation rating against the Brivis R1.0 minimum, the joints and fastenings, any crushed or collapsed runs, and whether the duct sizes suit the new heater's airflow.
A conversion to reverse cycle brings a test of its own, since YourHome says ducts need to be larger if they are also used for cooling, so heating-only ducts may need part or full replacement on that route. The duct and outlet line on a quote is the one that shows which of these the installer has priced, and it is worth asking about directly if a quote does not mention the ducts at all.
Homeupkeep's gas ducted page estimates that a typical Melbourne home running a gas ducted heater 4 to 6 hours daily through winter spends $850 to $1,800 on gas. That is the guide's own estimate, built around its idea of a typical home, and it is not a Brighton figure. The real cost depends on the gas tariff, the heater's efficiency, the house and how it is used, which Rinnai's Brivis page sums up as home size, usage and gas prices. The same guide says newer 6-star units run 30 to 40% cheaper than 3-star units, which is the running-cost argument behind the star rating chosen at the quote.
Energy.gov.au, the Australian Government's energy advice site, describes ducted gas heating as expensive to operate because of significant gas consumption and the electricity used by the fans. Two owner habits move the bill as well. Braemar's owner's manual says a return air filter left uncleaned makes the heater run inefficiently, and an inefficient heater results in higher gas bills. On some of its models the manual also lets the maximum gas rate be capped at 25%, 50% or 75% for times when less heat is needed, such as when some outlets are closed.
Zoning, covered in the last section of this page, lets part of the house be heated rather than all of it. No electric ducted running figure is given here, because none of the sources researched for this site prices one; the electric options appear in the replacement section below.
Peak Air Conditioning Brighton
Hydronic heating is not installed under this page, but it is the other whole-home system a buyer weighs, so the comparison is set out here. YourHome describes hydronic systems as circulating hot water or another fluid through radiator panels in rooms or under the floor, heated by electric heat pumps, solar collectors, or gas for heating only, where a ducted system moves warm air through outlets. The three parts below compare the warm-up, the upfront cost and the noise.
Ducted heating starts quickly. Brivis's operation manual says to allow approximately one minute for the burners to generate heat before the fans start, and Braemar's owner's manual says the heater and room fan start after a short delay of approximately 30 to 60 seconds once the set temperature is above the room temperature. From then the outlets deliver air well above room temperature: the Brivis Classic commissioning example is return air at 20 °C plus a 35 °C rise, giving 55 °C at the outlet on a floor outlet system.
Hydronic heating is slower to bring a cold house up. The Quote Yard's Victorian hydronic guide says it takes longer to warm a cold house than ducted air does, and Daikin's underfloor heating FAQ says its system may take slightly longer than conventional heaters to reach the target temperature. Daikin's Altherma heat pump heats its water to between 15 and 60 °C, well below the air temperature at a ducted outlet, which fits the slower climb those sources describe.
YourHome notes that in larger rooms with high ceilings a combination of radiant and convective heating is best, so the choice is not always one or the other. On these sources, the speed of moving air suits a house that is heated in bursts, such as mornings and evenings, while the slower start of a radiant system matters less in a house kept warm through long, steady periods.
No dollar figure is given here for hydronic installation, because no independent cost guide in the research for this site publishes one: the hydronic cost page checked on 19 November 2026 returned a not-found error, and the seller guides found carried their tables as images. What the official and independent sources say is qualitative, and it points one way. Energy.gov.au says that for hydronic radiant systems, purchase and installation costs are high, but running costs are lower when powered by solar or electric heat pumps. The Quote Yard's hydronic guide says hydronic costs more upfront than ducted air. YourHome says hydronic systems are typically more expensive to buy and install compared with space heaters, a comparison against room heaters rather than ducted systems, so it is quoted only for what it says.
The discount picture differs too. The Victorian Energy Upgrades heating and cooling discount page, read in full on 20 November 2026, does not mention hydronic heating anywhere, so no discount is assumed for it; the same page does list household discounts for replacing a ducted gas heater with ducted reverse cycle.
The installation work differs in kind. The Quote Yard notes that hydronic needs only small pipes where ducted heating needs duct routes through the roof or subfloor, and that a gas fired boiler is a Type A gas appliance, so a hydronic boiler needs the same licensed gasfitter as a ducted heater. The gas ducted prices to set against all of this are in the cost section above.
A ducted heater moves air, and moving air makes some sound. The Brivis Classic manual treats noise as a design item: ducts sized with curves and bends smooth enough for the air to flow efficiently and quietly, registers and diffusers large enough and of good design to minimise noise, and a return air grille large enough to take the system's full air capacity at low noise levels. Braemar's owner's manual covers the owner's side. Lowering the room fan speed reduces air flow noise, but it also reduces heat output and the spread of warm air around the house, and its Night Quiet Mode lowers the fan speed over the night period.
Hydronic systems are quieter by design. Energy.gov.au says their operation is silent and they don't distribute dust particles, a statement about air movement rather than about health. Daikin says underfloor heating is hidden, preserving wall and floor space, where radiator panels take a section of wall in each room they heat.
Ducted outlets sit flush in the floor or ceiling, so neither system crowds a room, but a ducted heater needs roof or underfloor space for its ducts, which Rinnai lists among the considerations on its Brivis page. On the Brivis guidance, outlet and duct sizing are where a ducted system's noise is designed out, which makes them worth checking on the quote for a bedroom wing.
Peak Air Conditioning Brighton
This section is about when to replace a gas ducted heater, not how to find a fault in one: error codes, servicing and the checks that find faults are set out under ducted heating service and repairs. Energy Safe Victoria's heating advice frames the decision in one line: if your heater is old, or hasn't been serviced for several years, consider replacing it. The four parts below cover age, repairs that cannot be made, a failed heat exchanger, and whether the new heater runs on gas.
Homeupkeep's Melbourne guide, a cost guide rather than a manufacturer, says to replace the whole unit at 15 to 20 years, and elsewhere on the same page advises planning financially for replacement at 18 to 20 years regardless of condition. No manufacturer document read for this page gives a service life in years. The Brivis Classic installer's manual and Braemar's owner's manuals give none, and Braemar's TG3 guide says only that periodic maintenance will ensure a long and satisfactory service life. Rinnai's figure of 12 to 20 years is for its ducted air conditioners, not its gas heaters, so it is not used here.
Age matters for a second reason: the ratings on offer have moved. A heater fitted 15 or more years ago may carry a rating near the bottom of a range that now runs to 6 stars on Rinnai's Brivis page, and homeupkeep's view that 6-star units are 30 to 40% cheaper to run than 3-star units is its case for replacing on efficiency as well as age.
The heater's own label is where the inspection starts. Braemar's TG3 guide says a data label on the end of the heater details its model number and gas type, and Braemar's owner's manual has a panel for the installer to record the model, serial number and installation date. An old heater that still runs well is not automatically due; age is a reason to plan, and the next three parts are the reasons to act.
Some heaters reach the end because a repair cannot or should not be made, whatever their age. Better Health, the Victorian Department of Health's site, says some heaters cannot be repaired for safety reasons and, sometimes, spare parts are not available for older heaters. For a very old heater, it says it may not be possible or worthwhile for your service person to repair it, and its advice is to be advised by your licensed gasfitter. Energy Safe Victoria adds that you should not attempt to fix your gas heater yourself, because gas work is not a DIY project.
That decision comes out of a service visit or a fault call, when the gasfitter finds a part that is no longer made, a fault that cannot be made safe, or a repair whose cost approaches that of a new heater. The diagnosis belongs to that visit, and this page picks up once the answer is to replace.
What helps at that point is having the facts ready: the heater's model and age from its data label, whether the ducts are sound, and whether the house is rented, because a rental property's choices change from 1 March 2027, as the last part of this section explains. The replacement can be like for like, a higher star rating on the same ducts, or a move to electric, and each option can be priced on the same inspection so the owner compares them side by side.
As a general rule of how gas ducted heaters work, the heat exchanger is the part where the burners' heat passes into the house air while the combustion gases go out through the flue. Brivis lists it among the core components a service covers, alongside the burners, the ignition system and the fan assembly. When it fails, the repair is a large one.
Homeupkeep's Melbourne guide prices heat exchanger parts and labour at $1,200 to $2,800, a figure to read against the new-heater ranges in the cost section above, which start at $3,800 to $5,200 for a 3-star 16 kW heater supplied and installed. On those figures a heat exchanger repair on a small heater can reach a large share of the price of a new one, and the repair keeps the old heater's star rating, while a replacement can move up the range.
Whether a heat exchanger has failed is a diagnosis for the gasfitter's visit, made under the service and repair process linked at the top of this section, and it is not described here. What the owner brings to the choice is the rest of the picture: the heater's age, its star rating, the state of the ducts, and whether other parts are close to the end of their life. A heater that needs a heat exchanger and then further work soon after is a different proposition from one that needs a single repair and has years of sound running behind it.
Replacing a gas ducted heater with another gas heater is still allowed in an existing home. The Victorian Government's existing residential buildings page, last updated 9 October 2026 and read on 20 November 2026, says there is no requirement to replace existing gas space heating, that buildings already connected to gas can remain connected, and that existing gas appliances can continue to be used, maintained and repaired as usual. It also says homeowners are encouraged to switch to efficient electric alternatives.
New building work is treated differently. The Gas Substitution Roadmap page says that from 1 January 2024 new homes requiring a planning permit are required to be all-electric, and the government's new buildings page says that from 1 January 2027 all new homes, including full knock-down rebuilds, must be built all-electric where the building permit is issued on or after that date. Rentals have their own rule: Consumer Affairs Victoria's heating standard says that from 1 March 2027, when an existing fixed heating system fails and cannot be repaired, it must be replaced with an energy-efficient fixed electric heating system, and its table lists gas ducted heating in that group. The ABS 2021 Census counts 23.7% of Brighton's occupied dwellings as rented, against 28.5% for Victoria.
The bill side is simple. The government's all-electric page says a dual-fuel home pays 2 bills and 2 service charges, and an all-electric home 1 bill with 1 service charge, with savings of around $1,900 a year for an existing home without solar, or around $2,230 with solar, from switching gas appliances to efficient electric ones. Those are whole-home figures, so they apply only once the last gas appliance goes, not to the heater alone. The electric options for a ducted home, including a hybrid indoor unit in the old heater's position and room systems, are set out under reverse cycle air conditioning. These government pages were read during the caretaker period before the 28 November 2026 state election, so check the current versions before relying on a date.
Peak Air Conditioning Brighton
The heater makes the heat; the outlets, the return air and the zones decide where it goes and how evenly. Each part below is drawn from the Brivis Classic installer's manual and YourHome, with Braemar's owner's manuals for the controls, and each is settled at the design and commissioning stages rather than after the heater is running.
Warm air rises, and that sets the first choice. YourHome says floor outlets are often better than ceiling outlets for heating, as warm air naturally rises, and that ceiling outlets can work too, particularly when rooms are sealed from draughts to the outdoors. The Brivis manual gives the typical sizes used on domestic heating systems: 300 mm x 100 mm floor registers and 150 mm round ceiling diffusers, each on a 150 mm duct connection.
As a general rule of how duct routes work, the outlet type follows where the ducts can run: ducts under the floor feed floor registers from below, and ducts in the roof space feed ceiling diffusers from above. Keeping the existing outlet type when a heater is replaced avoids new duct routes, while changing it means new runs and new holes in floors or ceilings, which is why it is decided at the quote.
The two outlet types are also commissioned differently, because the Brivis manual sets a higher temperature rise for floor outlet systems than for ceiling ones, covered in the last part of this section. Braemar's owner's manual adds a rule that applies to both: do not fit filters to warm air outlet registers. The filter belongs in the return air grille, and the next part covers where that grille should sit when the outlets are in the ceiling.
Every ducted heater draws air back from the house through a return air grille, and its height matters when the outlets are overhead. The Brivis manual says that if the system uses high level outlets such as ceiling diffusers, the return air inlet should be at a low level, and that ceiling systems with a high level return air may result in reduced performance. As a general rule of how air moves, warm air from a ceiling diffuser stays high in the room, so a return grille up there can draw it back to the heater before it has warmed the lower part of the room.
The manual also sizes the grille. It should be large enough to accept the system's full air capacity at low noise levels and minimum resistance, and its table gives minimum sizes by model: 0.20 square metres for a 2PW20N without a filter and 0.29 square metres with one, because a filter restricts the flow. Braemar's owner's manual says the return air grille is part of the ductwork and is usually fitted by the installer to a wall or ceiling inside the house, with the filter inside it, and the Brivis manual asks for that filter to be easily accessible for regular cleaning.
Brivis's operation manual notes one more effect of a ceiling return: fumes from candles, oil burners, cooking or smoking may be drawn into the system, especially if the return air inlet grille is in the ceiling, and can cause staining around the outlets. On a ceiling outlet system the manuals' guidance points to a low wall position, checked against the house layout at the inspection.
Zoning shuts parts of the house off, and a gas heater still needs somewhere for its air to go. The Brivis manual is direct: for all systems, a minimum number of outlets must remain fully open, counting both the outlet grille and the damper in the duct, if the heater is to operate properly without overheating. Its outlet table, set out as per AGA specification, gives each model a minimum and, for ceiling systems, a maximum. A BX315 moving 498 litres a second has a maximum of 8 and a minimum of 4 open outlets, a 2PW20N a maximum of 13 and a minimum of 7, and a 2PW26N a maximum of 17 and a minimum of 8.
A zone plan therefore has to leave at least the minimum open in every combination of zones the household will actually use. Newer heaters help. Rinnai lists the Buffalo BX5C as ZonePlus compatible with up to 4 zones and the StarPro 6 and 5 as ZonePlus and Adaptive Zoning compatible, and Brivis's operation manual says the network controls in its SP and BX5C heaters automatically adapt heater output to suit the number of outlets that are open.
Braemar's owner's manual covers the controls. When outlets are closed and the room fan speed is reduced, at least 1 outlet must remain open at all times, and a reduced maximum gas rate is meant for times when some outlets or vents have been closed. Braemar's TG3 guide puts the owner's check in one line: make sure there are enough outlets open for the fan speed selected.
Each outlet has a balancing damper, and the Brivis manual gives starting positions for a correctly designed and installed system: living areas 100% open, bedrooms 50% open, and bathrooms, ensuite and laundry 25% open. That weights the airflow towards the rooms used most. The fan is then set to the outlet type. On a floor outlet system the manual asks for a 35 to 40 °C rise over the return air temperature at the outlet nearest the heater, and on a ceiling or high level system a 25 to 30 °C rise. If the outlet air is hotter than recommended a higher fan speed is selected, and if it is cooler, a lower one. The final check is that the warm air at any outlet is not more than 45 °C above the return air temperature.
The thermostat completes the balance. The Brivis manual places it in the area most used for living, on an internal wall approximately 1,500 mm above the floor, and away from warm air outlets, sunlight, draughts and return air inlets, so that it reads the room rather than the air stream. Braemar's owner's manual recommends that owners keep the room fan settings their installer set, which is the commissioning result in daily use.
The Brivis manual adds that a ceiling outlet system can run efficiently with more than its maximum outlets open if it has been properly balanced, which is why the balance is set room by room at commissioning rather than left at the starting positions.

After the first call, a technician visits to look at the rooms to be heated or cooled, the walls, roof space or subfloor where equipment could go, the switchboard and any gas supply. The Victorian Energy Upgrades buyer's guide advises having installers check what size suits the home, because a system that is too large can use more energy and cost more to run.

The written quote names the system and its heating and cooling capacity, the unit positions, the pipe or duct route, any electrical or gas work, any approvals needed and the price of each option. Where a VEU discount applies, an accredited provider applies it before work starts, because the energy.vic.gov.au page says retrospective discounts are typically not possible.

The units are fitted, and the refrigerant pipework is pressure tested and evacuated before the system is charged. A licensed electrician does the wiring and issues a Certificate of Electrical Safety, and any gas work is done by a licensed gasfitter. Handover covers the modes, filter cleaning and the documents to keep.
Melbourne cost guides give two views. Whatsthedamage's Melbourne table puts gas ducted heating supplied and installed at $4,000 to $11,550, with $7,350 typical, while homeupkeep's guide runs from $3,800 to $5,200 for a 3-star 16 kW heater to $7,200 to $10,000 for a 6-star 30 kW heater. Both are indicative estimates, not quotes, and neither is Peak Air Conditioning Brighton's price. The figure for a particular home moves with the star rating and kW, the outlet count, access to the roof or subfloor, any gas pipe or meter work and removal of the old heater, and a written quote follows an inspection.
A gas ducted heater does not cool; it heats only. Cooling can be added in two ways: by keeping the heater and fitting an add-on cooling coil and outdoor unit to the same ducts where the model allows it, or by replacing the heater with a ducted reverse cycle system that heats and cools. Rinnai lists add-on cooling for its Brivis StarPro and Buffalo heaters, while the Brivis Classic manual says Classic heaters have no on-board add-on cooling connections. YourHome notes that ducts need to be larger if they are also used for cooling, so the existing ducts are checked first.
It depends on the house, the tariffs and the system, and manufacturer claims point both ways, so government sources are the better guide. YourHome notes that electric ducted systems may also be used for cooling, which gas ducted heating cannot do. The Victorian Government's all-electric page says an all-electric home pays 1 energy bill with 1 service charge, against 2 of each for a dual-fuel home, and Victorian Energy Upgrades heating and cooling discounts apply only to approved high-efficiency reverse cycle systems. Existing homes may keep gas heating, but new homes and knock-down rebuilds with a building permit issued from 1 January 2027 must be all-electric.
Homeupkeep's Melbourne cost guide says to replace the whole unit at 15 to 20 years, and to plan for replacement at 18 to 20 years regardless of condition. The Brivis and Braemar manuals read for this page give no service life in years, but Braemar's owner's manual says keeping to its maintenance requirements will prolong the heater's life. Better Health recommends that all gas heaters, central heating units included, are serviced at least every 2 years by a licensed gasfitter. Energy Safe Victoria advises considering replacement if a heater is old or has not been serviced for several years.
Yes. The usual route is a ducted reverse cycle system, which may reuse sound ducts, although YourHome says ducts need to be larger if they are also used for cooling. Seeley International also offers the Braemar Dominator, a hybrid indoor unit designed to fit the same position as a ducted gas heater and paired with a new outdoor unit. The old heater is disconnected and its gas supply capped by a licensed gasfitter registered with the Building and Plumbing Commission. The Victorian Energy Upgrades page lists household discounts for this swap of up to $2,520, $4,200 or $5,530, depending on the size of the new system.
The size comes from a heat load calculation, not from the number of bedrooms. Rinnai's Brivis page bases heater sizing on total floor area, ceiling height, insulation and glazing, orientation and climate zone, and says installers use a whole-of-home heat load calculation. The gas ducted heaters on that page run from 15 kW to 35 kW, and the Brivis Classic manual sets a minimum and maximum number of open outlets for each model, so the heater size and the outlet plan are worked out together. Peak Air Conditioning Brighton confirms the kW at the inspection and names it on the written quote.
GET A FREE QUOTE