Ducted air conditioning Brighton VIC 3186 puts one indoor unit in the roof space, runs it from a single outdoor unit and sends heated or cooled air through ducts to grilles in each room. Peak Air Conditioning Brighton plans reverse cycle ducted systems, cooling added to an existing gas ducted heater, and systems built into new homes and renovations. The roof space is inspected before anything is quoted: the duct route, the hanging point and service access for the indoor unit, and a return air path from every room. The written quote names the indoor and outdoor models, the kW capacity, the zone count, the damper type and the outlet positions. Refrigerant work is done under an ARC refrigerant handling licence and the wiring by a licensed electrician. Call or send an enquiry between 6am and 10pm, seven days a week.
GET A FREE QUOTE
Two things shape how a heating or cooling job in Brighton starts: knowing what each option costs before anything is booked, and finding a visit time that suits the household. Peak Air Conditioning Brighton is set up around both. Prices are put in writing after the site visit, option by option, and the phone line takes bookings for new systems, servicing, aircon cleaning and repairs from 6am to 10pm, seven days a week.
Peak Air Conditioning Brighton
Ducted air conditioning in Brighton comes in three forms, and the right one depends on what the house already has. Mitsubishi Electric describes a ducted system as an indoor unit hidden in the ceiling space that heats or cools the air and sends it through a network of ducts to vents in each room, with an outdoor unit that houses the compressor and condenser. The three parts below cover a new reverse cycle system, cooling added to a gas ducted heater that stays, and ducting planned into a build or renovation.
A ducted reverse cycle system heats and cools the whole house from one outdoor unit and one indoor unit, through the same set of ducts. Mitsubishi Electric explains that ducted reverse cycle, also known as a heat pump, works in two directions: in cooling mode it extracts heat from inside the home and releases it outdoors, and in heating mode the process reverses, drawing heat energy from the outside air and moving it indoors, even in cool conditions. The federal YourHome guide describes the same system from the heating side: ducted air heaters can make heat with gas or electricity, and the electric systems may also be used for cooling. That is the practical difference from gas ducted heating, which whatsthedamage notes only heats and needs a gas connection and a flue, so cooling becomes a second system. YourHome adds a design point for one duct network doing both jobs: ducts need to be larger if they are also used for cooling. A reverse cycle system is therefore laid out with duct sizes set for cooling airflow as well as heating, and the zone controller sends that air to the rooms in use in either season. Mitsubishi also points out that one outdoor unit serving every room takes up less space outside than a set of separate split systems.
Add-on cooling keeps a working gas ducted heater and adds a refrigerated coil and an outdoor unit to the same duct network, so the house gains cooling without replacing the heater. Rinnai, of which Brivis is now part, lists Brivis ICE add-on cooling for its gas ducted heaters. Its range page describes the Buffalo BX5C as a good match for ICE add-on cooling, lists the StarPro 6, 5 and 4 as ICE and DualComfort compatible, and gives ICE DualComfort at 13 to 22 kW for StarPro heaters and ICEbox DualComfort at 10, 13 and 15 kW for Buffalo heaters, with duct work in the roof space or under the floor. Seeley International also lists ducted add-on cooling systems in its Braemar range. Compatibility is decided model by model, and the Brivis sources point both ways on one series: the Rinnai page lists the Classic Compact as compatible with ICE add-on cooling, while the Brivis Classic installer's manual says Classic ducted gas heaters do not have on-board add-on cooling connections. So the heater's series and model plate are read at the inspection before add-on cooling is quoted. Whether the existing heating ducts are big enough for cooling airflow is the second check, for the reason YourHome gives above. The heater itself is gas work: its burner and flue, and any fault found before the cooling goes in, sit with ducted heating service and repairs, done by a gasfitter registered with the Building and Plumbing Commission.
A new build or a major renovation is the easiest time to fit ducted air conditioning, because the ceiling is still open. Mitsubishi Electric says that on new home builds the installer may fit the indoor unit, ductwork, refrigerant piping and electrical work before the plasterboard goes up, and install and connect the outdoor unit later. Daikin says its ducted systems can be installed in a new home or tailored to suit an existing one, and Rinnai lists building or renovating among the times ducted suits a house. Planning early also means the duct layout and the roof insulation are designed together, and YourHome advises reflective foil insulation under the roof and venting to dispel hot air from the roof space. On a renovation, Mitsubishi's PEA-M-HAA units come in two pieces, which it describes as ideal for home renovation because they can be installed through a ceiling access. Brighton sits in the City of Bayside, and Bayside City Council's heritage page says a planning permit may be required to alter or extend a building in a Heritage Overlay, so an extension's outdoor unit position is worth raising with the council in the same planning round. The renovation drawings are the right place to mark the indoor unit, the return air grille and every supply outlet before the framing closes them in.


Peak Air Conditioning Brighton
A ducted installation is mostly roof-space work: the indoor unit is hung, ducts are run to every outlet, and the unit is set up for the ductwork it ends up with. The five steps below follow Mitsubishi Electric's PEA-M100-160HAA ducted installation manual (September 2023) and the federal YourHome guide. The refrigerant pressure test, evacuation and outdoor work follow the same rules as any refrigerated installation; what follows is the part that is specific to ducted.
A ducted job is decided in the roof space before it is quoted. Mitsubishi Electric says a qualified installer assesses the roof space to choose the most suitable route for the ductwork and the position of the indoor unit, and that the work needs access to the ceiling cavity. Its PEA-M manual asks for the route to carry the unit into the roof to be settled before installation, and for a site where the ceiling can carry the unit's weight, the refrigerant piping can be led easily to the outside, the supply and return air are not blocked and the supply air can reach the whole room. The manual also rules out a site with a fire detector on the supply air side, because warm air in heating mode can set it off. Melbourne installer QuickAir names the roof space among the variables behind a ducted quote, along with floor plan, ceiling height, insulation, window orientation and the number of zones, and says shallow or cluttered roof cavities are consistently the harder jobs. Rinnai lists the inputs to the whole-of-home heat load calculation that sets the system's size: total floor area, ceiling height, insulation and glazing, orientation and climate zone, the method covered under air conditioning installation. The inspection records the roof framing, the access hatch, the existing insulation and any old ducts, and the duct route is drawn from those notes.
The PEA-M manual hangs the indoor unit on M10 hanging bolts, with the ceiling reinforced where needed to keep it level and stop vibration, and it says the unit must be hung level, checked with a level, so that the drain discharges. The condensate drain then runs away on a downward slope of 20 mm per metre or more, with a drain trap shown in the manual's drain diagram. On the two-piece PEA-M-HAA, the fan unit can be separated from the coil unit to pass through a ceiling opening, but the manual says neither half may be suspended alone: the two are joined again before the unit is hung. Service access is planned at the same time. The manual asks for enough space to maintain, inspect and replace the motor, fan, drain pump, heat exchanger and electric box, with that space not blocked by beams, and it shows access doors of 450 x 450 mm and 600 x 600 mm where there is 300 mm or more clear below the unit. It also says the refrigerant pipe connections must stay accessible for maintenance. Where the air above the ceiling runs hot and humid for long hours, above a dew point of 26 °C, the manual calls for 10 to 20 mm of extra insulation over the entire surface of the unit to stop condensation forming on it.
The ducts are where a ducted system can give away its efficiency, so the run is laid out to keep losses small. YourHome says duct runs should be straight with all joints tightly taped, that ducts must be insulated to at least R1.5 with joints sealed to prevent condensation and leakage, and that ducts kept inside the conditioned part of the house perform better. It warns that ducts which are not adequately insulated and sealed risk condensation, air leakage and lost heating or cooling. Mitsubishi Electric adds that ductwork carries an R-value, a measure of the material's thermal resistance, and that higher values reduce the load on the air conditioner. At the unit, the PEA-M manual fits a canvas connector between the unit and the duct, calls for incombustible material in the duct parts, and asks for full insulation on the inlet flange, the outlet flange and the outlet duct to prevent condensation. It sets an inlet duct length of 850 mm or more, keeps loads of 3 kg or heavier off the inlet flange, and says a space such as a false ceiling must never be used as a duct for the air inlet or outlet. Keeping the runs straight once the ducts go in depends on following the route drawn at the roof inspection rather than improvising around obstacles on the day.
As a general rule of airflow, a room can only take in as much supply air as can find its way back to the unit. YourHome calls a return air path from every outlet back to the central system important: without one, the conditioned air escapes and the system sucks in unconditioned air, which it says dramatically reduces effectiveness. Its remedy is simple: in each room with a duct outlet, a gap under the door between that room and the central return air inlet creates the path. Mitsubishi Electric describes the cycle from the unit's end: the system draws air from the home through a return air grille, passes it over the refrigerant coil in the indoor unit and sends it back out through the ducts. The PEA-M manual puts the air filter in the inlet grille, fitted before the inlet duct is connected, and its function table sets a filter reminder at 100 or 2,500 hours, while Mitsubishi's zone controller can prompt the owner when the filter needs cleaning. The return grille therefore goes where the filter can be reached from below without climbing into the roof. Rooms with doors that close tightly to the floor are noted at the inspection, because a door with no gap shuts the path YourHome describes, and the fix is chosen before the outlets are cut.
External static pressure is, as a general rule, the resistance that the ducts, filter and grilles put against the indoor unit's fan, and a ducted unit is set to match it. The PEA-M manual tells the installer to change the external static pressure setting depending on the duct and the grille used, with settings of 50, 100 or 150 Pa chosen through the function menu, and to record any change in the check column of the function table. Mitsubishi Electric lists its PEA-M-HAA range at high external static pressure up to 150 Pa, the low-profile PEAD-M-JAAD at 35 to 125 Pa and the larger PEA-M-LAA at up to 250 Pa, so the unit choice and the duct layout are matched to each other. Its zone controller brochure says the installer set-up wizard in the Mitsubishi app can set the external static pressure, the filter hours and the fan speed during heating thermo-off. The setting is chosen once the duct lengths, the outlet count and the grille types are known, which is why it comes after the duct run rather than before it. Recording it in the function table means the next technician to open the system can see what was set and why.
Peak Air Conditioning Brighton
Peak Air Conditioning Brighton takes bookings from 6am to 10pm, seven days a week, and the written quote follows a roof space inspection. Mitsubishi Electric says the installer must hold a refrigerant handling licence to install a ducted air conditioner, and refrigerant work on these systems is done under an ARC licence. The two steps below are what a ducted system needs before it is handed over: airflow balanced zone by zone, and the electrical and test run checks that the manufacturer's manual sets out.
Air balance is the installer's commissioning step, done once the ducts and zone dampers are in. Mitsubishi Electric's zone controller brochure (May 2026) describes an Air Balance Function that lets the installer set maximum opening positions for the zone dampers so the airflow can be balanced between zones. It is available on the on/off models as well as the linear ones, so balancing is possible on every installation that uses the controller, and the brochure notes that it means less time in the ceiling. The installer set-up in Mitsubishi's app includes a quick air balance step alongside the zone settings and the sensor assignment. As a general rule of duct design, zones on short duct runs tend to take more air than zones at the end of long runs, and the maximum opening positions even that out. YourHome's ducted guidance asks for adjustable outlets and for systems designed and installed by accredited experts, which is the same work seen from the outlet end. The positions set at commissioning are worth writing on the handover sheet, so that a later change to the house, such as a room closed off or a zone added, can be rebalanced from a known starting point rather than from scratch.
Before a ducted system runs for the first time, the PEA-M manual sets out a sequence of checks. The installer looks for refrigerant leakage, loose power or control wiring, wrong polarity and a disconnected phase, then uses a 500 V megohmmeter to confirm at least 1.0 MΩ between the power supply terminals and earth, a test the manual says is not done on the low-voltage control wiring. It explains that a fresh installation can read below 1 MΩ because refrigerant collects in the compressor, which is not a fault, and that the reading rises once the compressor has warmed for two to three hours. Power then goes on at least 12 hours before operation starts, and the manual warns that starting straight after switching on the main power can badly damage internal parts. The unit runs on an exclusive circuit, with an earth leakage breaker where the manual calls for one, wired by a licensed electrician; Energy Safe Victoria says the customer receives a copy of the Certificate of Electrical Safety. The test run then checks that cool air blows in cooling mode, warm air blows in heating mode, and the fan speed changes when the fan setting is changed. The manual adds that wind can slow, stop or even reverse the outdoor fan during the test, which is not a problem.


Peak Air Conditioning Brighton
Melbourne cost guides publish indicative ranges for ducted reverse cycle, and whatsthedamage says the band a home lands in depends mostly on its size, how many storeys it has and how finely it is zoned, more than on the brand. The figures below are those guides' estimates, not prices set by this business, and the written quote follows a roof space inspection. Brighton's housing gives the context: 57.2% of its occupied dwellings are separate houses and 33.1% have four or more bedrooms (ABS 2021 Census), against 73.4% and 32.6% for Victoria.
whatsthedamage's Melbourne table (updated November 2026) has two bands. A standard ducted system for a three-bedroom home, or a single-storey four-bedroom home with good roof access, is $8,400 to $14,700, with $11,550 typical. A premium or zoned system for a larger four-bedroom home and up, a two-storey home or room-by-room zoning is $12,600 to $23,100, with $16,800 typical, and the page adds that two-storey homes or complex layouts sit at the top of the range. QuickAir's Melbourne guide prices installed systems by bedroom count: $5,000 to $8,000 for a small one or two-bedroom home, $8,000 to $10,000 for a medium three or four-bedroom home, $8,000 to $14,000 as the typical three to four bedroom outcome, and $10,000 to $25,000 and up for large or multi-storey homes. hipages gives national figures, last updated 28 March 2025: $5,000 to $8,000 for an apartment or small home, $6,000 to $10,000 for an average three or four-bedroom single-storey home, and $10,000 to $25,000 for a large multi-storey home. Two-bedroom dwellings make up 27.4% of Brighton's housing (ABS 2021), and for those whatsthedamage says ducted can be more system than the home needs, setting a two-head multi-split at $4,200 to $7,900 against the $8,400 floor of its standard band. The sources do not say how many Brighton homes are two-storey, so the storey count is read at the inspection rather than assumed.
Within a band, the guides name the same drivers. whatsthedamage says each extra zone adds its own damper and controls, a low or crowded roof cavity makes every duct run slower and harder, and a full or older switchboard may need upgrading before the outdoor unit can be connected; its whole-home scenario includes zoning of usually two to four zones, a thermostat and commissioning. hipages lists the type of ducted system, the size and layout of the home, zoning, the building materials, the roof space available and the complexity of the job, and says the more points and zones added, the higher the cost. Daikin puts it as home size, number of zones and system complexity. The controller is a line of its own. Mitsubishi Electric's zone controller brochure lists a main wall controller, a zone controller interface concealed in the ceiling and field-supplied damper motors, then optional items: a wireless receiver, wireless zone remotes, wireless or wired temperature sensors and a Wi-Fi adapter. None of the three cost guides, read on 20 November 2026, gives a dollar figure per zone or per outlet, so no per-zone price is assumed here. Instead the written quote lists the zone count, the outlet count, the damper type and each controller item, so two quotes for the same house can be compared line by line.
Replacing a ducted system does not always mean replacing the ducts. Mitsubishi Electric says existing ductwork may be compatible with a new ducted air conditioner, depending on its condition and on the new unit's size and capacity, and that replacing it with higher-rated ductwork may be more cost-effective over time because it reduces the load on the system. Rinnai notes that ducting may last longer than the mechanical components. The checks on old ducts are the ones YourHome sets for any duct: insulation to at least R1.5, sealed joints with no air leakage, and a size that suits cooling airflow. Where the ducts are replaced, whatsthedamage's Melbourne table prices whole-house ducted heating ductwork with new insulated flexible ducts at $2,000 to $6,300, with $3,775 typical; that row is written for heating ductwork, and because cooling ducts may need larger sizes, as noted above, a cooling duct set is priced on its own sizes at the quote. For an old evaporative system, whatsthedamage says its ductwork can sometimes be reused if it is the right size and in good condition, but evaporative ducts are often larger than a reverse cycle system needs. For older R22 ducted systems, Daikin lists R22 retrofit capability on its Premium Inverter ducted range, aimed at retrofitting an old R22 ducted system.
Peak Air Conditioning Brighton
Ducted and split systems both move heat with a refrigerant heat pump; the difference is how the air reaches each room. Daikin frames it as split systems for individual rooms and ducted systems for whole-home coverage, with one central unit serving several zones instead of several outdoor units. The two parts below set the energy side and the layout side against each other. Room-by-room installs, including multi-head splits on one outdoor unit, are planned under split system installation.
YourHome says ducted systems are less energy efficient because they need energy for fans to push the air around the house through the ducts, and that they lose heating or cooling through ducts that are not adequately insulated and sealed. A wall split has no duct run, so the duct-loss half of that does not apply to it. The other side of the comparison is how many rooms run at once. hipages says split systems are cheaper to run as individual units when only one or two rooms need cooling, but that cooling a whole home with several splits costs more to run in total than a ducted system. Daikin's FAQ says much the same: splits can be cheaper for single-room cooling, while ducted systems with zoning and inverter technology can be more efficient for whole-home heating and cooling over time. Those are a cost guide's and a manufacturer's views rather than measurements, and YourHome adds that zone settings which switch off parts of the home used less often can make central systems more efficient. Energy labels do not settle it either. The Energy Rating site says the Zoned Energy Rating Label is mandatory in store on non-ducted, unitary and single-split units, so a split carries a star label and a ducted system usually does not, and ducted offers are compared on the maker's own efficiency figures instead.
Inside the house, Daikin says a ducted system leaves only the controller, the return air grille and the discharge grilles visible, while a split system puts an indoor unit on the wall of each room it serves. Mitsubishi Electric frames ducted for homes with several rooms or large open-plan spaces, with one outdoor unit in place of several and the wall space left free. Outside, separate splits each need their own outdoor unit, and a multi-head split runs several indoor units from one, but Mitsubishi says all units on the same outdoor unit must run in the same mode, either heating or cooling. A ducted system also runs in one mode at a time: Mitsubishi's zone controller selects heat, cool, auto, dry or fan only for the whole system, and on linear models a temperature for each zone. Outlet position matters for heating. YourHome says floor outlets are often better than ceiling outlets for heating because warm air rises, and that ceiling outlets can work too, particularly when rooms are sealed from draughts. Daikin mounts its wall splits high for better airflow and circulation. Rinnai lists sufficient roof or ceiling space for ductwork as a requirement of ducted, so a house without it is planned with split systems instead.


Peak Air Conditioning Brighton
The indoor unit is chosen to fit the ceiling depth first and the capacity second. Daikin's ducted range runs from Premium Inverter and Inverter ducted units to Slimline and Bulkhead models and two underfloor variants, and Mitsubishi Electric's runs from low-profile PEAD units to the PEA-M series; ActronAir also makes ducted systems built for Australian conditions. The brands are named as plain information, and the four parts below cover the unit types and what each needs from the house.
A standard ducted unit suits a roof space with the height and access to move it in, hang it and service it. Mitsubishi Electric's PEA-M-HAA series comes in 10.0, 12.5 and 14.0 kW, with the PEA-M160HAA at 16 kW, all with high external static pressure up to 150 Pa and a two-piece construction the maker calls ideal for existing homes. For larger homes, its PEA-M-LAA series runs from 18 to 24.5 kW, with 16 kW and 18 kW single-phase models available. Mitsubishi notes that single-phase 240 V power is the residential standard, that three-phase 415 V is generally used for large-capacity units, and that the right supply should be confirmed when the unit is chosen. Daikin lists its Premium Inverter for small to large houses and heating or cooling the entire home, and its Inverter series for houses with limited roof space and outdoor space, built to fit the tight roof space of a modern home. These capacities are a range to choose from, not a sizing rule: the heat load calculation picks the kW, and the roof inspection confirms that the unit and its service space fit where it will hang.
Where the ceiling space is shallow, a slimmer unit goes in. Mitsubishi Electric's PEAD series stands 250 mm high across its 5.0 to 14.0 kW range, which it says lets ducted air conditioning go into low ceilings and tight bulkhead cavities where a conventional ducted unit will not fit; the current PEAD-M-JAAD listing adds a built-in condensate pump and external static pressure from 35 to 125 Pa. As a general rule, a built-in pump lifts condensate where the drain cannot fall away from the unit by gravity. Daikin's Slimline is designed for installations where ceiling space is at a premium, listed for narrow ceiling spaces and for heating or cooling several rooms, while its Bulkhead range suits drop ceilings and shallow ceilings where a discreet installation is wanted. Mitsubishi draws one line between the two: a bulkhead system is designed to air-condition a single room, while a ducted system serves several. The ceiling depth measured at the inspection decides which of the two the space can take, and whether a pump model is needed for the drain.
Underfloor ducted units sit beneath the house and deliver air through floor outlets. Daikin lists Premium Inverter Ducted Underfloor and Inverter Ducted Underfloor models, both for underfloor installation in small to large houses, and calls them an ideal solution for homes in colder climates where heating is a focus. YourHome explains why floor outlets suit heating: warm air naturally rises, so floor outlets deliver heat where it is most needed, while cold air coming in under external doors can form a layer above the floor that keeps warm air from ceiling vents from heating the room. Rinnai also describes ducted systems with ducts under the floor and vents in the floor. For Brighton, the Energy Rating calculator allocates postcode 3186 to the Cold climate zone, a label allocation rather than a statement that any house needs an underfloor system. An underfloor unit needs room beneath the floor for the unit and its ducts, so the subfloor height and access are checked at the inspection; a house built slab on ground has no subfloor to use.
The compressor is where a unit's efficiency starts. Daikin lists variable-speed inverter compressors for precise temperature control among the key features of its ducted systems, and says most of them use R-32 refrigerant and inverter technology for reduced energy consumption. As a general rule of how inverters work, the compressor speeds up and slows down to match the load rather than switching fully on and off. Mitsubishi Electric says ducted systems can be an energy-efficient choice when properly sized and installed, and gives its ducted models EER ratings for cooling and COP ratings for heating so that models can be compared. The PEA-M manual's test run notes that the outdoor fan's speed is controlled to suit the unit's performance too, turning slowly when the load allows. Rinnai says modern ducted systems are highly efficient when correctly sized, zoned properly and used with insulated ductwork, which ties the unit's rating back to the work in the roof. On a written quote, the model's EER and COP figures are the numbers to set side by side when comparing two ducted offers.
Peak Air Conditioning Brighton
Zoning splits the duct network into areas that can be switched on or off. Mitsubishi Electric's own example is to cool the living areas during the day and switch to the bedrooms at night, and Daikin gives the heating version, warming bedrooms at night and keeping living areas cool by day. YourHome says zoned systems cool only the occupied areas and allow different conditioning in living and sleeping areas. The three parts below cover the zone count, the damper type and what happens when most zones are shut.
Zone counts vary by maker, and Mitsubishi Electric's own pages disagree. Its ducted product page, read on 20 November 2026, says the Zone Controller can create up to 4 or 8 separate zones, while its zone controller brochure, dated May 2026, offers the controller in 4 or 10 zones, as the PAC-ZC04 and PAC-ZC10 models in on/off and linear versions. Both figures are given here as each source publishes them. Rinnai lists up to 8 individual zones on its ducted reverse cycle range, and Braemar's Dominator comes with four RF sensors as standard and can be expanded to 8 zones. Mitsubishi's brochure defines a zone as a room the installer has configured for independent control of airflow or temperature, and its product page says the right zoning depends on the floor plan, lifestyle and the capacity of the ducted system. whatsthedamage's whole-home scenario assumes usually two to four zones. In Brighton, 33.9% of dwellings have three bedrooms and 33.1% four or more (ABS 2021), but no source sets a number of zones per bedroom, so the zone plan follows how the rooms are used, which rooms are used together, and the system's capacity.
The damper type is the owner's choice, and it sets how fine the control is. Mitsubishi Electric's brochure offers on/off damper control, which opens or shuts each zone, and linear damper control, which it describes as full temperature control. Linear models set an individual temperature in each zone in 0.5 °C steps, and their Adaptive Temperature Control reads temperatures every few minutes and adjusts the airflow into each zone, using a Mitsubishi temperature sensor or wireless zone remote in each zone. Several sensors can be connected to one zone to average its temperature, which the brochure suggests for open-plan spaces or for several bedrooms served by a single zone motor. One system takes up to 10 wireless sensors or zone remotes and 4 wired temperature sensors, and the wireless ones need a wireless receiver in the ceiling. The damper motors are field supplied, 24 VAC drive-open drive-closed, and the brochure says motors from different makers can be mixed on one system. It also says the controller works with all current and some older Mitsubishi indoor units, so an older system can be upgraded, with a backing plate to cover the old controller's mark on the wall. A weekly schedule of up to 10 patterns can switch zones on and off.
When most zones are shut, the fan is still moving air and that air needs somewhere to go; as a general rule of duct design, a spill zone is an area left open to take the excess. Mitsubishi Electric's brochure shows two layouts for this, a spill zone layout and a common zone layout. On its linear models, a Dynamic Spill Zone opens the spill zone only by the smallest amount needed, triggered when the total open ratio of the zones falls below a threshold the installer sets, so that excess airflow is managed correctly while comfort in the spill area improves. The main controller's fan speed can also be set to auto, which the brochure says adjusts the fan to suit the active zones. The area used as the spill or common zone is chosen on the floor plan at the inspection, as a space that can take extra air without bothering anyone in it. A single bedroom zone running overnight, with every other zone shut, is the kind of case the spill setting is planned for, and the threshold is set at commissioning to suit the house.


After the first call, a technician visits to look at the rooms to be heated or cooled, the walls, roof space or subfloor where equipment could go, the switchboard and any gas supply. The Victorian Energy Upgrades buyer's guide advises having installers check what size suits the home, because a system that is too large can use more energy and cost more to run.

The written quote names the system and its heating and cooling capacity, the unit positions, the pipe or duct route, any electrical or gas work, any approvals needed and the price of each option. Where a VEU discount applies, an accredited provider applies it before work starts, because the energy.vic.gov.au page says retrospective discounts are typically not possible.

The units are fitted, and the refrigerant pipework is pressure tested and evacuated before the system is charged. A licensed electrician does the wiring and issues a Certificate of Electrical Safety, and any gas work is done by a licensed gasfitter. Handover covers the modes, filter cleaning and the documents to keep.
whatsthedamage's Melbourne guide says a single-storey four-bedroom home with good roof space usually still fits its standard band of $8,400 to $14,700, toward the top, while two storeys, a larger floor plan or room-by-room zoning move it into the premium band of $12,600 to $23,100. QuickAir gives $8,000 to $14,000 as the typical three to four bedroom outcome in Melbourne, and hipages' national guide, last updated in March 2025, puts an average three or four-bedroom single-storey home at $6,000 to $10,000. These are guide estimates rather than quotes. Peak Air Conditioning Brighton gives a written quote after a roof inspection, listing the zones, outlets and controller items.
Neither is better in every house. Daikin presents split systems as the choice for individual rooms and ducted for whole-home coverage, and hipages says splits cost less to run when only one or two rooms need cooling. A ducted system hides everything but the grilles and controller, runs from one outdoor unit and can be zoned, while YourHome notes that it uses fan energy and can lose heating or cooling through its ducts. Rinnai adds that ducted needs sufficient roof or ceiling space for the ductwork, so the roof inspection settles whether it is an option at all.
Upfront it costs more than a single split, and Daikin lists a higher upfront cost than single-split systems among the disadvantages of ducted. Running costs depend on the system's size and type, the hours it runs, the set temperature, the electricity tariff and how well the house is insulated (hipages), plus fan energy and any duct losses (YourHome), and zoning cuts the area being conditioned. whatsthedamage puts a ducted system service in Melbourne at $210 to $580 per visit, with $345 typical. None of the sources used here gives a reliable Melbourne running cost for ducted reverse cycle, so no running figure is stated.
Mitsubishi Electric says the right zoning depends on the floor plan, lifestyle and the capacity of the ducted system, and no source sets a fixed number of zones per bedroom. Controllers set the upper limit: Mitsubishi's product page says 4 or 8 zones and its May 2026 brochure says 4 or 10, while Rinnai lists up to 8. Both Mitsubishi Electric and Daikin describe the same pattern, living areas conditioned by day and bedrooms at night, which is one way to divide a house into zones. Peak Air Conditioning Brighton sets the zone plan with the owner at the inspection and lists it on the quote.
Yes. Mitsubishi Electric says ducted air conditioning can be installed in an existing home, with a qualified installer assessing the roof space for the duct route and the indoor unit position, and the work needing access to the ceiling cavity. Daikin notes that retrofitting into existing homes can be more complex, and Rinnai that it may require additional installation work. Two-piece units such as Mitsubishi's PEA-M-HAA are made to go up through a ceiling access, and slimline units suit shallow roof spaces.
Daikin says that with proper care and maintenance its ducted systems can last 10 to 15 years or more. That is the manufacturer's own figure for its own systems, not a promise for any one unit, and the outcome depends on the care it describes. Daikin's maintenance advice is to clean the indoor filters regularly, keep vents clear and book annual professional servicing to maintain efficiency and extend the system's life.