Evaporative cooler service Brighton VIC 3186 covers the roof-mounted ducted cooler from the water inlet to the wall control: the pads, the tray and water distribution, the bleed or dump valve, the pump, the fan and the cabinet, checked before summer so the cooler is ready ahead of the first hot week. Peak Air Conditioning Brighton also repairs the faults owners notice from inside the house, such as warm air from dry pads, a noisy fan or slipping belt, and a musty smell at the first start of the season. At the end of summer, the winter shutdown drains the cooler and closes its path into the house. Each visit ends with a written service record, and any repair is priced in writing before a part is ordered. Calls and enquiries are taken from 6am to 10pm, seven days a week.
GET A FREE QUOTE
Two things shape how a heating or cooling job in Brighton starts: knowing what each option costs before anything is booked, and finding a visit time that suits the household. Peak Air Conditioning Brighton is set up around both. Prices are put in writing after the site visit, option by option, and the phone line takes bookings for new systems, servicing, aircon cleaning and repairs from 6am to 10pm, seven days a week.
Peak Air Conditioning Brighton
This first section covers the cooler itself and the two jobs that decide how it performs each summer. It explains what a ducted roof unit is and how it cools, why the service is booked before the season rather than during it, and why the filter pads are treated as a part that wears out. The individual checks made on the roof are set out in the next section.
A ducted evaporative cooler is a single cabinet on the roof that cools the whole house through ducts in the ceiling. energy.gov.au describes how it works: outside air is drawn through the unit, generally on the roof, blown over a film of water held on a filter or sponge, and forced into the house, where it pushes the hot indoor air out through open windows and doors. Inside the cabinet, The Quote Yard explains, a pump lifts water from a reservoir at the base of the unit to spray nozzles or trough outlets at the top of each pad, and a fan drives the cooled air down into the ducts. There is no refrigerant circuit and no compressor, which is why an evaporative service is a water, pad, pump and fan job rather than a refrigerant check.
Roof cabinets on the market include Breezair, Braemar and Coolair, all Seeley International brands, and the Brivis range, which Rinnai now sells under the Brivis name. Portable evaporative coolers are a separate product: energy.gov.au says they are less effective at cooling a room and can warm it unless air can flow to the outside, and they are not what this page covers. Brighton has a smaller share of separate houses than Victoria as a whole, 57.2% against 73.4% (ABS 2021 Census), but the census does not record which homes have an evaporative cooler, so this page makes no claim about how common they are.
Timing is most of the value of an evaporative service. The Quote Yard's evaporative guide recommends annual professional servicing before the cooling season, so the cooler is ready ahead of the first hot week rather than found wanting on it. The reason is the winter in between. The same guide names stagnant water, corrosion and frost damage as the risks for a cooler that sits idle for months, and the first start of the season is when any of them shows up.
Recommissioning is the spring half of that cycle. The Quote Yard describes it as confirming that the system has come out of its winter dormancy without developing problems: the water system is filled and tested, the fan and pump are run to confirm they work, and the controls are adjusted. The manufacturers set their own minimums. Seeley International's owner's manuals for its Breezair and Coolair coolers ask for the full maintenance schedule every 2 years in a home, performed before summer, and add a seasonal service before and after every summer for coolers fitted with a bleed system. Seeley's manual for its Braemar LCB and BM and Coolair CPL and CPS models asks for the drain-valve components to be checked after the first year, then every 2 years. So the interval that applies depends on the model and its water system, and the annual pre-summer booking is a cost guide's advice, not a regulation. Booking in spring also leaves time for a part to be ordered if recommissioning finds one that needs replacing.
Filter pads are the consumable part of an evaporative cooler, the part expected to wear out and be replaced. The Quote Yard puts replacement at every two to five cooling seasons and gives three reasons for the spread: the quality of the water, the hours the cooler runs, and the type of pad material. Water quality matters because evaporation leaves minerals behind on the pad face, and The Quote Yard says harder regional water speeds up scale formation on the pads. Melbourne's supply works in Brighton's favour here, since the same guide describes Melbourne's water as generally soft with low mineral content, which it calls favourable for evaporative cooling.
Hours matter because a cooler that runs most days of a long summer passes more water through its pads, and leaves more behind, than one used on a few hot afternoons. Material matters because pads differ by maker: Seeley's Breezair coolers use its Chillcel pads, and its maintenance schedules list them as an item to check, clean if required and replace if required. The warning sign is easy to miss. The Quote Yard notes that a cooler with clogged pads pushes warm air while running exactly as it always did, and calls pad condition the first thing to check when performance drops off. Seeley's pre-season steps for its Braemar and Coolair models say to wash the pads gently, never with a high pressure water spray, and to replace them if they are in poor condition. The service record gives an estimate of the seasons a set has left, so a replacement can be planned rather than discovered on a hot day.


Peak Air Conditioning Brighton
The service follows the cooler from the water inlet to the wall control. The Quote Yard lists the scope of an annual service as pad inspection and possible replacement, cleaning and adjusting the water distribution system, pump inspection, dump valve testing, a fan motor and bearing check, belt inspection where a belt is fitted, and checking the controller works. The four checks below are the ones that most decide how the cooler runs; the fan and belt checks are covered with the noise faults further down the page.
Every drop that reaches the pads starts in the tray, so the tray and the distribution system are cleaned and set first. The Quote Yard describes the circuit: a pump draws water from a reservoir at the base of the unit and sends it to spray nozzles or trough outlets along the top of each pad. Seeley's service checklist for its Braemar and Coolair models works through it in the same order: the base and water reservoir, the pump and its filter basket, the water probes, the water distribution system, then the washers, seals and o-rings. Its end-of-season steps add checking and cleaning the lid water channels, and its troubleshooting for some Coolair models points to debris in those channels as the cause of dry patches.
With the parts clean, the water level is set. Seeley's checklists include the float valve, the water level set point and the water fill time, the settings that decide how much water sits in the tray for the pump to draw on and how quickly it refills. The last test is visual. The pad frames are refitted, the cooler is run, and the pads are watched to confirm they wet evenly with no dry spots, which is the wording on Seeley's own checklist. A channel that runs short on one corner leaves that part of the pad doing no cooling, however clean the tray is, so the distribution is adjusted until water covers the full face of every pad.
Evaporation takes water out of the tray and leaves its salts and minerals behind, so every evaporative cooler needs a way to flush them out. Seeley's manuals describe two systems. A continuous bleed drains small amounts of water while the cooler runs, so fresh water keeps diluting the salt that builds up. A drain valve, often called a dump valve, empties the tray when it is needed: on Breezair coolers the WaterMiser system uses salinity probes to open the drain valve when the water reaches a preset level, and Coolair's WaterManager can drain on salinity or on a timer of 1 or 2 hours of running. The Quote Yard says the bleed is what keeps the tray water from concentrating, that it is the part most often disabled to save water, and that turning it off saves a trivial amount of water while sharply shortening pad life.
The service tests the system the cooler actually has. On a bleed cooler, the bleed funnel is cleaned and the flow confirmed, since Seeley says the installer sets the bleed rate to local operating conditions and its checklist includes the bleed rate where one is required. On a drain-valve cooler, the valve and solenoid are cleaned and their operation checked, the probes are cleaned, and the drain time is confirmed. The Quote Yard adds that the dump valve can be set to flush the reservoir more often where the water is hard; Melbourne's softer supply is covered in the pad section above. Any bleed that has been switched off is put back into service, and the setting the cooler is left on is written on the record.
Brighton sits within the City of Bayside on the Port Phillip coastline (Wikipedia), and salt in coastal air is why the cabinet check sits on this page. The Quote Yard's air conditioning repairs guide names Brighton among the bayside suburbs, from Williamstown around through Brighton, Mordialloc and Frankston, where outdoor units corrode at the coil and the cabinet. That passage is about outdoor air conditioning units in general, not evaporative coolers, but a roof-mounted cooler sits in the same air all year. The Quote Yard's evaporative guide lists corrosion among the risks for a cooler left idle over winter.
Seeley's end-of-season steps for its Braemar and Coolair models say what to inspect: the external cabinet for any damage or deterioration, the dropper duct and flashing for signs of corrosion, and the water supply valve for correct operation and leaks. The cabinet's material changes where the attention goes. Seeley says it developed the first corrosion-free, all-plastic rooftop cooler, and that its Coolair range was redeveloped with the same all-plastic construction, so on those cabinets the metal around the unit becomes the focus: the dropper duct that carries air down into the roof space, the flashing where the cooler meets the roof, and the support frame that Seeley's installation checks list with the roof penetrations. Anything found is described on the service record, so its progress can be compared at the next visit. Nothing here depends on how far a home is from the beach, a figure no source gives; the inspection settles what the cabinet and its fittings actually show.
The last check is the part the owner uses every day. The Quote Yard ends its service list with controller operation verification, and Seeley's schedules ask for the wall control to be checked in all modes, with the airflow through the system and outlets checked at every fan speed. Seeley's manuals describe three ways a cooler runs: at a constant fan speed, to a temperature target where the fan speed varies to get as close to it as possible, or in a fan-only mode that circulates air without cooling it, shown as VENT on its MagIQcool controls. Each mode is run before the visit is signed off.
Fan-only is worth more than it looks. The Quote Yard notes that running the fan without the pump moves cool outside air through the house at almost no cost once the outside temperature drops below the inside, and adds a caveat: confirm it against the manufacturer's manual. The controller also reports faults. On Seeley's MagIQcool controls a flashing Service message comes with a number, and the manuals list two that an owner can check: 02, which points to the water supply tap being off or the supply being interrupted, and 04, which points to a blocked drain on coolers with a drain valve. Any code that appeared over the summer is checked against the cooler before sign-off. Seeley also notes that some settings are locked for installers and service technicians only, so changes such as the salinity setting are made at the service rather than guessed at from the wall.
Peak Air Conditioning Brighton
Peak Air Conditioning Brighton takes calls and enquiries from 6am to 10pm, seven days a week. What an owner can hold each visit to comes down to two documents: a written record of what was checked, set and replaced, and a written repair price agreed before any part is ordered. Both are described below, including the one service visit that belongs to the cooler's manufacturer rather than to this business.
After each visit the owner receives a written record of what was found and done. It lists the condition of the pads and an estimate of the seasons they have left, which water management system the cooler has and how the bleed or dump valve was left set, the results of the pump, float valve, fan motor and belt checks, the controller test, anything noted on the cabinet, dropper duct or flashing, and every part replaced. That is the information needed to plan the next pad change, to compare this year's cabinet with last year's, and to price a repair against a replacement when the time comes.
The record has a use beyond the owner's own file. Seeley's owner's manuals carry a maintenance schedule with a service record table for each visit, by service date, technician and company, and its warranty terms say each schedule item must be performed at the stated frequency by a qualified, licensed technician, with the schedule properly filled out with names, signature, date and action taken. Seeley's warranty page adds that the receipted service invoice should be kept with the warranty certificate. One visit is not this business's to do: for Breezair and Braemar coolers under Seeley's seven-year warranty, the general maintenance service in the fourth year must be performed, and charged for, by Seeley International or its nominated appointee, so owners in that window book that service through Seeley. For Brivis coolers, Rinnai's page says its Service Advantage Program extends cover when the product is registered and scheduled servicing is completed. The Standards Australia page for AS/NZS 3666.2 also lists maintenance records in its contents and evaporative air-cooling equipment among the equipment it covers; it is named here only as a standard that treats records as part of maintenance, with no claim that it applies to a given home.
A repair follows a fixed order: find the fault, name it and the part, then wait for the owner's yes before anything is ordered or fitted. Diagnosis comes first because several evaporative faults look the same from inside the house. Warm air can come from dry pads, a pump that has stopped, a house closed up against the airflow or simply a humid day, and only some of those need a part. Guessing at the cause risks replacing a part that was working.
Once the cause is found, the owner gets a written note naming the fault, the part or parts needed, whether a part has to be ordered, and the work involved, with the price stated before work starts. For a Seeley cooler the part named is a genuine Seeley part, because Seeley's manuals say only new factory authorised replacement parts should be used, and that other parts may void the factory warranty and lead to improper and unsafe operation. If the owner wants time to decide, or to set the repair against replacing the cooler, nothing is ordered until they confirm. Owners can help the diagnosis before the visit. Seeley's manuals ask owners to write down the number that flashes with a Service message, and quoting that number when booking tells the technician where to start looking on the roof.


Peak Air Conditioning Brighton
Published figures for evaporative servicing come from cost guides, not invoices, and none of them is this business's own price. They show what a fair quote looks like and what moves it. The three parts below cover the annual service, the drivers of a repair price, and what the cooler costs to run. The written quote for a Brighton home follows an inspection of the cooler and its roof access.
Two Australian cost guides publish evaporative service figures. hipages, last updated on 27 January 2026, gives $250 to $350 nationally and says the figure depends on the size of the home. The Quote Yard's Victorian servicing guide, published on 7 September 2026, gives $150 to $350 for evaporative cooling service across Victoria and narrows it for Melbourne: its text puts an evaporative unit serviced before summer, including pad inspection and water system checks, at $180 to $320, and its Melbourne table shows $170 to $330 for a pre-summer evaporative service with the pads checked.
The word checked is the important one. Those Melbourne figures cover inspecting the pads, not replacing them, so a service that finds pads at the end of their life becomes a service plus a pad replacement, priced as a separate line. No pad price is quoted on this page, because the cost guide that lists one gives a range in its table and a different range in its text for the same job. What it does give consistently is the interval of every two to five seasons, depending on the water. All of these figures are indicative estimates rather than quotes, and none of them includes repairs. A written quote for a Brighton home states the service price and any pad replacement separately, once the cooler and its pads have been seen.
No cost guide publishes a call-out fee for evaporative repairs specifically. The nearest published figure is for air conditioning repairs in general: The Quote Yard's Victorian repairs guide gives attendance and diagnosis at $120 to $250, says the call-out is usually credited against the repair if it goes ahead, and its Melbourne table gives call-out fees from $120 to $280 across its five Melbourne regions. Its suburb list, read on 19 November 2026, puts Brighton under "Bayside & Peninsula", which has no fee row of its own, so the call-out for a Brighton visit is confirmed at the quote.
Parts are the second driver, and they depend on what failed. Seeley's maintenance schedules list the pump, drain valve, solenoid, probe, float valve, motor, fan and bearings, and electronics box as items to replace if required, and no source gives a price for any of them. Seeley's warranty terms also treat cooler pads, washers, seals and drive belts as consumables after the first year. Roof access is the third driver. Seeley's manuals say servicing may carry extra charges where the roof pitch is over 30°, access to the roof is limited, the roof material or its condition does not allow safe access, the access point is more than 4 metres above the ground, the cooler sits too close to a fall edge, or the roof cannot carry the cooler and the technicians, covering the equipment or extra labour needed for safe access. A low roof with an easy ladder position and a high or steep roof are priced differently for that reason, and the quote says which applies.
An evaporative cooler's running cost has two parts, electricity and water. The Quote Yard explains why the electricity side is low: the cooler draws a fan motor and a small pump rather than a compressor. energy.gov.au gives the comparison: ducted evaporative coolers use less than half of the electricity consumed by an air conditioner of similar capacity. It adds that ducted models with inverter-driven fan motors use much less power than those without, especially on the lower fan speeds, and YourHome notes that some modern evaporative coolers use far less energy than older models, advising owners to check with manufacturers.
Water is the other side. energy.gov.au gives water use of up to 25 litres per hour, and YourHome advises checking with the council for any water restrictions. The service has a bearing on both. Clogged pads and a poorly wetted pad face mean less cooling for the same fan power, and the water setting the cooler is left on decides how much water goes down the drain: Seeley says its WaterMiser high salinity setting runs the cooler at a maximum safe salinity level and results in a minimum usage of water, while its low setting is for specific circumstances only. No source gives a dollar figure per hour for running a cooler in a Brighton home, so none is given here; the electricity side depends on the fan motor and the hours run, and the water side on the setting and the weather.
Peak Air Conditioning Brighton
An evaporative cooler and a refrigerated system cool a house in opposite ways. The Quote Yard sets them side by side: a refrigerated system cools regardless of outdoor conditions and runs with the house sealed, while an evaporative cooler depends on dry air and needs doors or windows partly open. The three differences below decide whether an existing cooler still suits a Brighton household: the weather, the windows and the winter.
Evaporative cooling works by evaporating water into the incoming air, so the drier the air, the more it cools. The Quote Yard describes the best case in Melbourne terms: on a hot, dry northerly day, the sort that arrives ahead of a cool change, an evaporative system performs superbly, and dry northerly days are what it was designed for. The humid day is the opposite. Melbourne gets several each summer, according to the same guide, and on those days the air already carries moisture, so the temperature drop shrinks and the cooler pushes air that feels warm and damp. The Quote Yard is blunt about what that means: nothing is broken and no service call will fix it. Seeley's manuals say the same thing in their troubleshooting tables: when humidity is high, the cooler will not reduce the temperature as much as on drier days.
Location shifts the balance. energy.gov.au says evaporative coolers work well in low-humidity inland regions and lists reduced effectiveness on humid days among the trade-offs. The Quote Yard says coastal and bayside areas carry more humidity, which narrows the number of days the system performs well, and that Melbourne's bayside suburbs have higher summer humidity than the western and northern suburbs, while the cooler remains effective on the dry, hot conditions of most summer days. By that guide's own grouping, Brighton, which it lists under Bayside, falls on the more humid side. Its advice for those days is practical: watch the humidity rather than the thermostat, and when the temperature drop is not happening, switch the cooler off rather than run it harder.
A refrigerated system is run with the house closed; an evaporative cooler is run with it open. The Quote Yard explains that the cooler pushes a continuous volume of outside air into the house and that air has to escape somewhere, and energy.gov.au describes the cooled air expelling the hot indoor air through open windows and doors. The Quote Yard calls this the most common reason a new owner thinks the cooler is not working.
Seeley's manuals put numbers on it. In each room with an outlet, open the windows or doors farthest from the vent and provide an exhaust opening about 2 times the vent size, or 2 to 2.5 times in its Braemar and Coolair manual. That manual also gives the total minimum opening for the whole house by model, from 2.0 square metres for its smallest coolers to 4.0 square metres for its largest, and notes that an average door is about 1.5 square metres. Where the design of the house prevents enough exhaust, Seeley suggests mechanical extraction such as an exhaust fan. Its troubleshooting tables list insufficient exhaust openings as a cause of inadequate cooling, alongside dry pads and humidity, so a complaint of weak cooling starts with the windows before anyone goes on the roof. YourHome adds one exception to open-house running: when outside air quality is low, for example during bushfires, it may be necessary to limit the cooler's use.
An evaporative cooler only cools. The Quote Yard says it does nothing in winter, and Rinnai's Brivis evaporative page lists among its considerations that it does not provide heating and may not achieve precise temperature control. So a house with an evaporative cooler needs a separate system for winter, and the two sit side by side for the life of the cooler, each with its own servicing.
For an owner weighing up an ageing cooler, that is the real comparison. Keeping the evaporative cooler means keeping two systems: the cooler for summer and a heater for winter. A refrigerated system can do both jobs from one unit. A reverse cycle air conditioning system heats in winter and cools in summer, and The Quote Yard notes that refrigerated cooling works regardless of outdoor humidity, which removes the humid-day limit described above. The trade the same guide names is a higher purchase price and higher running costs than evaporative cooling. This page does not compare heating systems or their efficiency, because that choice sits with the heating pages. For servicing, what a cooling-only cooler does mean is a changeover each autumn and spring, set out in the winter section below.


Peak Air Conditioning Brighton
Most evaporative faults show up in one of three ways from inside the house: the air is not cool, the fan is louder than it was, or the cooler smells when it starts. Each has normal behaviour that can look like a fault, and causes that need a technician on the roof. The last part covers the point where repair stops being worth it and the cooler is better replaced.
When an evaporative cooler blows warm air, the first question is whether water is reaching the pads. Seeley's troubleshooting tables list dry pads as the first cause of inadequate cooling, with two owner checks: make sure the water supply is turned on, then check the water flow to the pads. Its controllers help, since a Service message with the number 02 points to the supply tap or a supply interruption. A few minutes of uncooled air at start-up is normal. Seeley's manuals say the cooler takes a few minutes to start as it fills with water and saturates the pads, and its Braemar and Coolair models run a Pre Cool Cycle that wets the pads before the fan starts, so that only cool air enters the building.
Past that, the faults sit in the water circuit. The pump can stop or lose flow, its filter can block, the float valve can hold the water level too low, the water solenoid or its filter can fail, and the distribution channels can block so part of a pad stays dry; Seeley's schedules list each of these as a part to check and replace if required. Each one leaves the pads dry or patchy while the fan keeps running, which is why the house gets plenty of air but little cooling. The repair is found by watching the water: whether the tray fills, whether the pump lifts water, and whether it spreads across every pad. If the pads are wet, the pump is running and the house is open but the air is still warm, the weather may be the cause: a humid day is not a fault, as the comparison section above explains.
The Quote Yard's service scope includes a fan motor and bearing check and belt inspection and tensioning where applicable, and the words where applicable matter. Seeley's schedules list the pulley and belt as items fitted on some models only, so not every cooler has a belt to slip. On belt-driven models, a belt that has worn or lost tension can slip on its pulley, which is why tensioning is part of the check; Seeley lists the pulley and belt to check, adjust and replace if required, and its commercial schedule asks for belts to be checked for wear every year on coolers that run more than 3,200 hours a year. Seeley's warranty terms count drive belts among the consumables, which tells an owner a belt is expected to wear out in normal use.
On every model, the fan and its bearings are checked, adjusted or replaced as needed, and Seeley's pre-season steps for its Braemar and Coolair models include checking the fan motor, mounts and blades for damage. Their checklist also covers motor operation, with the motor amps set where required. Not every change in sound is a fault. A cooler running to a temperature target changes fan speed as the room warms and cools, and Seeley's controllers offer a night quiet mode that restricts fan speed overnight, so a cooler that sounds different at night may simply be on that setting. A new noise that does not follow the fan speed, or one that appears with a vibration through the ceiling, is the cue to book a check, and the service record notes the bearing and belt condition so wear can be compared from one season to the next.
A musty smell in the first minutes of the season has a known cause. The Quote Yard explains that a tray left full through winter grows organic matter in the standing water, and the fan then blows that smell through the house at the first spring start-up. It adds that draining and drying the system at the end of the season prevents this entirely, and the steps for that are set out in the winter shutdown section below. This page treats the smell only as an odour fault in the cooler; it makes no claim about air quality or health.
Once the smell is there, the fix is a clean-out: the tray is drained and cleaned, the pump filter and distribution parts are cleaned, the pads are flushed or replaced, and the drain system is checked. That last check matters, because a drain valve that fails to open leaves water standing in a cooler that was meant to empty itself; Seeley's manual for its Braemar and Coolair models says the drain valve opens on its own once the cooler has been off for 72 hours, and a 04 code on its controls points to a blocked drain. A second smell has a different cause. Seeley's troubleshooting tables list an odour from new pads, which fades after some hours of running and can be cleared sooner with the Pad Flush function or by filling, running the pump, draining and repeating. Some controllers can stop standing water forming at all: Seeley's Drain and Dry setting drains the tank and runs the fan for an hour at a chosen time each day, and Rinnai lists standby stagnant water clearing on its Brivis Advance coolers.
Some coolers reach the point where the next repair is money spent on an old cabinet. When that happens, The Quote Yard says like-for-like replacement on existing ductwork is the most common and cost-effective approach: the new unit is mounted on the existing roof curb and connected to the existing ductwork, water supply and electrical circuit. That only works if the ducts are sound, and the guide is specific about how to tell. Assessing the ducting means a roof cavity inspection, not a look from the ground, and worn ducting shows as deteriorated insulation, collapsed liners or disconnected joints.
Some parts are renewed even on a like-for-like swap. Seeley's manual says the new hose sets supplied with the appliance are to be used and that old hose sets from a previous installation should not be re-used. The Quote Yard notes the unit needs a dedicated circuit for the fan motor and pump, so the existing circuit is checked, and any electrical work is done by a licensed electrician, who issues a Certificate of Electrical Safety. Some owners use a replacement to change systems altogether. The Quote Yard says evaporative ductwork is sometimes reusable for a refrigerated ducted system, depending on the duct size, condition and insulation rating; what that switch involves is covered under ducted air conditioning. The repair-or-replace call is made on the inspected condition of the cabinet, the parts needed and the ducts, and the written quote sets out both options side by side so the owner can compare them. No new-unit price is given on this page.
Peak Air Conditioning Brighton
At the end of summer the cooler is put away for months, and two jobs need doing. The water side is emptied and isolated so nothing stands in the tray until spring, and the air path from the roof into the house is closed so winter heating does not escape up through it. The third part covers the order of the autumn and spring changeover in a home that also has a heating system.
The shutdown is the reverse of recommissioning, and The Quote Yard sets out the procedure: drain the water reservoir completely, turn off the water supply at the isolation valve, and clean the reservoir and water distribution components. Seeley's end-of-season list for coolers with a bleed system follows the same order with more detail: turn off the water supply, clean the water distributors, drain and clean the tank, clean the pump and the probe, and remove the bleed funnel and its o-ring and keep them for next season. Its manual for Braemar and Coolair models starts by turning off the power, checks the water supply valve for correct operation and leaks, and cleans the lid water channels, the tank and the pump filter, leaving the bleed system out until spring.
Coolers with a drain valve handle part of this themselves. That Braemar and Coolair manual says the drain valve opens on its own once the cooler has been off for 72 hours, Coolair's WaterManager offers drain delays of 3 hours, 12 hours or 3 days after the cooler is turned off, and the wall controls have a manual drain mode. The water supply is still turned off at the isolation valve, as The Quote Yard's procedure has it, and the tray is checked to confirm it has emptied. The Quote Yard gives the reasons for doing all this: stagnant water, corrosion and frost damage are the risks for an idle cooler, and the stale-water smell covered in the repairs section is the one an owner notices first.
An evaporative cooler is an open path from the roof into the house, and in winter that path works against the heating. YourHome explains the cost: built-in evaporative coolers can increase heating bills, because large volumes of air can be lost from the house through the ducting during the cooler months when the cooler is not in use. It gives two fixes. Many modern units have automatic seals when not in use; otherwise, close off the ducts and cover the roof unit in winter. The Quote Yard's shutdown procedure ends the same way, with covering the unit or closing its external dampers to stop cold air coming in during winter heating.
Which fix applies depends on the cooler. Rinnai lists a motorised winter seal on its Brivis Contour 6, Promina and Advance coolers and a counterbalance winter seal on the Balaero, and Seeley's maintenance schedules include a check of weatherseal operation. A seal is only useful if it closes, so at the shutdown visit it is run and watched closing fully, and a seal that sticks is recorded as a repair. On an older cooler with no seal, the choice is the one YourHome gives: cover the roof unit, or close off the ducts. The service record notes which arrangement the home has, so the same step is not missed next autumn. Whatever is fitted comes off again at recommissioning, before the cooler is started in spring, because a covered cooler cannot draw air through its pads.
Homes that pair an evaporative cooler with a heater hand over between the two systems twice a year. energy.gov.au notes that gas ducted heating can be paired with a ducted evaporative cooler to give temperature control across the year. The Quote Yard says households running evaporative cooling alongside gas ducted heating or split system reverse cycle heating have to manage that transition: shut the evaporative system down in late autumn and start the heating, then reverse it in spring with a professional recommissioning service.
The order matters in autumn. The cooler is drained, isolated and sealed or covered before the heating season begins, because YourHome places the heat loss through cooler ducts in the cooler months when the cooler is idle, which is exactly when the heater is running. In spring the order flips. The heating is switched off for the season, then the cooler is recommissioned, with its seal or cover removed, its water turned back on and its pump and fan run. The two jobs can be lined up with the heater's own maintenance. A gas ducted heater's servicing is gas work for a licensed gasfitter registered with the Building and Plumbing Commission, and it is set out under ducted heating service and repairs; this page covers only the cooler's side of the changeover, so the two visits are booked as separate jobs.


After the first call, a technician visits to look at the rooms to be heated or cooled, the walls, roof space or subfloor where equipment could go, the switchboard and any gas supply. The Victorian Energy Upgrades buyer's guide advises having installers check what size suits the home, because a system that is too large can use more energy and cost more to run.

The written quote names the system and its heating and cooling capacity, the unit positions, the pipe or duct route, any electrical or gas work, any approvals needed and the price of each option. Where a VEU discount applies, an accredited provider applies it before work starts, because the energy.vic.gov.au page says retrospective discounts are typically not possible.

The units are fitted, and the refrigerant pipework is pressure tested and evacuated before the system is charged. A licensed electrician does the wiring and issues a Certificate of Electrical Safety, and any gas work is done by a licensed gasfitter. Handover covers the modes, filter cleaning and the documents to keep.
Cost guides put a standard service at roughly $150 to $350. The Quote Yard's Victorian servicing guide gives $150 to $350 across Victoria and $170 to $330 in its Melbourne table for a pre-summer service with the pads checked, while hipages gives $250 to $350 nationally, depending on the size of the home. Those figures cover inspecting the pads, not replacing them, and they are indicative estimates rather than quotes. Peak Air Conditioning Brighton gives a written price once the cooler and its roof access have been seen.
The Quote Yard recommends a professional service every year before the cooling season, so the cooler is ready ahead of the first hot week. Seeley's owner's manuals set the full maintenance schedule every 2 years for a home, done before summer, and add a seasonal service before and after every summer for coolers with a bleed system. The schedule that applies depends on the model and its water system, so check the cooler's own manual. Owners of a Breezair or Braemar cooler under Seeley's seven-year warranty also need the fourth-year service done by Seeley or its nominated appointee.
Start with the pads. The Quote Yard calls pad condition the first thing to check, because clogged pads push warm air while the cooler seems to run normally, and Seeley's manuals list dry pads first, so check that the water supply is on and water is reaching the pads. Make sure windows or doors are open too, since too few exhaust openings is another listed cause. If the pads are wet and the house is open, the day may simply be too humid, and The Quote Yard says nothing is broken in that case. A pump, float valve or water distribution fault needs a technician on the roof.
Not by government figures. energy.gov.au says a ducted evaporative cooler uses under half the electricity of an air conditioner with the same capacity, and that models with inverter fan motors use much less again. The trade-off is water, up to 25 litres an hour on the same page, so YourHome suggests checking council water restrictions. The model matters as well: YourHome notes that some modern coolers use far less energy than older ones.
There is no single cut-off point given on this page. Rinnai's Brivis page describes evaporative cooling as most effective in hot, dry conditions and less effective as humidity rises, so the cooling fades rather than stopping at one figure. energy.gov.au lists reduced effectiveness on humid days, and The Quote Yard says bayside areas carry more humidity, which narrows the days a cooler performs well. The practical test is how the air feels: if the cooler is pushing warm, damp air, The Quote Yard's advice is to switch it off rather than run it harder.
Keep the bleed system switched on, because The Quote Yard says turning it off saves very little water and sharply shortens pad life. Run the cooler with windows or doors open, and on mild evenings try fan-only mode once it is cooler outside than inside, after checking your manual. Book a service before summer, and at the end of the season drain the tray using the wall control's drain mode and have the water supply isolated. Leave anything on the roof to a technician, since Seeley's manuals warn that climbing onto the roof can be hazardous.